Passive Nighttime Cooling: Historical Applications and an Evaluation of Energy-Efficiency Potential in Contemporary Buildings

Eesha Sinha

Princeton Journal of Pre-Collegiate Research · 2026

DOI: 10.67698/pjpcr.2026.0246 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Princeton Journal of Pre-Collegiate Research, 2026. Verfasst von Eesha Sinha.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As global temperatures rise and the demand for mechanical cooling increases, the energy-intensive nature of HVAC (Heating, Ventilation, Air Conditioning) systems presents a growing challenge to environmental sustainability. This prompted an interest in traditional architectural strategies that utilize natural environmental processes for thermal regulation. Passive night cooling techniques, employed in ancient architecture, offer a sustainable solution to cooling without consuming energy. A literature review of cooling techniques was conducted using peer-reviewed journal articles, reported data findings, and case studies focused on a hot/semi-arid climate. Ancient passive cooling techniques were analyzed through five mechanisms: thermal mass, night flushing, evaporative cooling, stack ventilation, and thermal sinks to evaluate the most optimal strategy for modern-day energy-efficient buildings. Historical examples were used to understand the scientific principles of cooling techniques and further used to evaluate the practicality of integrating these methods into an urban environment. The historical examples and their assessed practicality were then used to perform a comparative evaluation of each technique, based on its reported reduction in cooling energy demand. The findings demonstrated that the passive cooling techniques substantially reduce reliance on mechanical cooling systems, the most potent techniques being thermal mass and evaporative cooling, due to high reduction in cooling energy demand, easy integration of evaporative cooling, and low maintenance of thermal mass. Excluding individual techniques, the greatest overall potential was demonstrated by thermal sinks. Integrating this into modern-day buildings has high energy savings, due to the integration of several techniques. Collectively, these indicate that the greatest potential for energy-efficient buildings doesn’t require replicating ancient architecture but adapting multiple principles for an urban landscape.

Zitieren

APA

Sinha, E. (2026). Passive Nighttime Cooling: Historical Applications and an Evaluation of Energy-Efficiency Potential in Contemporary Buildings. Princeton Journal of Pre-Collegiate Research. https://doi.org/10.67698/pjpcr.2026.0246

Vancouver

Sinha E. Passive Nighttime Cooling: Historical Applications and an Evaluation of Energy-Efficiency Potential in Contemporary Buildings. Princeton Journal of Pre-Collegiate Research. 2026. doi:10.67698/pjpcr.2026.0246

BibTeX
@article{Sinha2026,
  author = {Sinha, Eesha},
  title = {Passive Nighttime Cooling: Historical Applications and an Evaluation of Energy-Efficiency Potential in Contemporary Buildings},
  journal = {Princeton Journal of Pre-Collegiate Research},
  year = {2026},
  doi = {10.67698/pjpcr.2026.0246}
}