Design of a Combined Load Frequency and Automatic Voltage Control System for An Interconnected Migrogrid Using Beluga Whale Optimizer (BWO) Tuned Fopid
Journal of Intelligent Computing and Engineering · 11.09.2026 · 2 (1) · 31-64
DOI: 10.67561/jice.v2i1.4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Intelligent Computing and Engineering, online erschienen am 11.09.2026. Verfasst von Ayuba Momodu und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Load Frequency and Automatic Voltage controllers play a significant role in ensuring the stability of an interconnected power system. These controllers require good tuning to ensure that optimal parameters fordesired power system performance are obtained. While several optimization techniques have been explored in the design of Load Frequency Control (LFC) and Automatic Voltage Regulator (AVR) system, the application of novel metaheuristic algorithms is presently receiving great attention. This study proposes the design and modeling of an interconnected Sustainable Energy Microgrid Load Frequency and Automatic Voltage Control using FOPID. For optimal performance, the intelligence of the Fractional Order PID (FOPID) controller will be enhanced through optimization using Beluga Whale Optimizer (BWO). Performance of the proposed optimized FOPID based controller will be evaluated through comparison with Particle Swarm Optimizer (PSO). The simulation results shows that BWO-FOPID Controller produced the best Frequency stability Performance for Area 1 with a settling time of 4.0s, Rise time of 13.924s and an overshoot of 3%. Accordingly, for Area 2, a settling time of 4.6s, Rise time of 84.365s and an overshoot of 2.5% was obtained from the frequency response. With respect to the Voltage stability For Area 1 a settling time of 3.3s, Rise time of 123.221s and an overshoot of 5% was obtained from the frequency response. For Area 2, a settling time of 5.3s, Rise time of 93.843s and an overshoot of 5% was obtained from the frequency response. Thus, the effectiveness of the proposed technique demonstrates the combined control strength of FOPID and the optimization effectiveness of Beluga Whale Optimizer
Zitieren
APA
Momodu, A., Alabi, I. I., Adunola, F. O., Dabo, A. I., Aliyu, S., Araga, I. A., Tureta, K. T., & Isah, A. I. (2026). Design of a Combined Load Frequency and Automatic Voltage Control System for An Interconnected Migrogrid Using Beluga Whale Optimizer (BWO) Tuned Fopid. Journal of Intelligent Computing and Engineering, 2(1), 31-64. https://doi.org/10.67561/jice.v2i1.4
Vancouver
Momodu A, Alabi II, Adunola FO, Dabo AI, Aliyu S, Araga IA, et al. Design of a Combined Load Frequency and Automatic Voltage Control System for An Interconnected Migrogrid Using Beluga Whale Optimizer (BWO) Tuned Fopid. Journal of Intelligent Computing and Engineering. 2026;2(1):31-64. doi:10.67561/jice.v2i1.4
BibTeX
@article{Momodu2026,
author = {Momodu, Ayuba and Alabi, Isaac Ibitayo and Adunola, Fatai Olatunde and Dabo, Abdulmalik Ibrahim and Aliyu, Sabo and Araga, Idris Adejoh and Tureta, Kabiru Tureta and Isah, Ahmad Idris},
title = {Design of a Combined Load Frequency and Automatic Voltage Control System for An Interconnected Migrogrid Using Beluga Whale Optimizer (BWO) Tuned Fopid},
journal = {Journal of Intelligent Computing and Engineering},
year = {2026},
volume = {2},
number = {1},
pages = {31--64},
doi = {10.67561/jice.v2i1.4}
}
EUVIMED