Electronic inspiratory muscle training in hospitalized patients: a systematic review
HTA Journal · 31.10.2026 · 1 (2) · 80-88
DOI: 10.67516/htaj.26.2.80 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift HTA Journal, online erschienen am 31.10.2026. Verfasst von Gisele da Silva Peixoto Zandoná und 9 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Respiratory muscle weakness is common in hospitalized patients, particularly in intensive care units, and is associated with worse clinical outcomes, such as prolonged mechanical ventilation and length of hospital stay. Inspiratory muscle training is a rehabilitation strategy performed using mechanical or electronic devices, the latter offering greater capacity for monitoring and load adjustment.
Objective
To critically analyze the evidence on the effectiveness of inspiratory muscle training using electronic devices compared with control conditions (sham training, T-piece/spontaneous breathing, or usual care/conventional physiotherapy) in hospitalized patients.
Methods
We searched MEDLINE (via PubMed), Embase, LILACS, and PEDro from inception to June 2026, without date or language limits, for randomized controlled trials in hospitalized patients. Risk of bias was assessed with RoB 2 and certainty of evidence (CoE) with GRADE; random-effects meta-analyses (DerSimonian--Laird) were performed.
Results
Eight randomized controlled trials (458 participants) were included. Maximal inspiratory pressure may increase after the intervention (MD 6.89 cmH₂O; 95%CI 0.11 to 13.67; low CoE). The evidence was very uncertain about shorter mechanical ventilation weaning time in the intervention group (MD −5.69 days; 95%CI −8.84 to −2.55; very low CoE). Weaning success did not differ between groups (RR 1.27; 95%CI 0.79 to 2.05; very low CoE).
Conclusion
Electronic inspiratory muscle training may improve inspiratory muscle strength and reduce mechanical ventilation weaning time in hospitalized patients. The certainty of evidence ranged from low to very low; the findings should be interpreted with caution. PROSPERO CRD42024539420.
Zitieren
APA
Zandoná, G. D. S. P., Algeri, É. D. B. D. O., Dorneles, G., Araújo, R. C. P. D., Silva, R. G. S. C., Sampaio, A. L. M., Medeiros, C. B. S. D., Loreti, E. H., Santos, I. M. D., & Negrão, F. J. (2026). Electronic inspiratory muscle training in hospitalized patients: a systematic review. HTA Journal, 1(2), 80-88. https://doi.org/10.67516/htaj.26.2.80
Vancouver
Zandoná GDSP, Algeri ÉDBDO, Dorneles G, Araújo RCPD, Silva RGSC, Sampaio ALM, et al. Electronic inspiratory muscle training in hospitalized patients: a systematic review. HTA Journal. 2026;1(2):80-88. doi:10.67516/htaj.26.2.80
BibTeX
@article{Zandon2026,
author = {Zandoná, Gisele da Silva Peixoto and Algeri, Éllen Daiane Biavatti de Oliveira and Dorneles, Gilson and Araújo, Rafaele Carla Pivetta de and Silva, Renato Guilherme Silveira Correa and Sampaio, Anderson Luis Mota and Medeiros, Camila Beatriz Souza de and Loreti, Eduardo Henrique and Santos, Israel Moraes dos and Negrão, Fabio Juliano},
title = {Electronic inspiratory muscle training in hospitalized patients: a systematic review},
journal = {HTA Journal},
year = {2026},
volume = {1},
number = {2},
pages = {80--88},
doi = {10.67516/htaj.26.2.80}
}
EUVIMED