EUVIMEDEUVIMED entdecken
Crossref

Complications of total implantable access ports and efficacy of Taurolidine-citrate lock solution against catheter-related infections

Emine Ince, Pelin Oğuzkurt, Abdulkerim Temiz, Semire Serin Ezer, Hasan Özkan Gezer, Nalan Yazici, Akgün Hiçsönmez

African Journal of Paediatric Surgery · 26.05.2026 · 11 (2) · 138-142

DOI: 10.67481/ajps.v11i2.492 ↗

Kurz gefasst

Fachartikel in der Zeitschrift African Journal of Paediatric Surgery, online erschienen am 26.05.2026. Verfasst von Emine Ince und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Totally, implantable access ports (TIAPs) are used for long standing venous catheterization. This study was designed to present our experiences of the TIAPs applications and efficacy of Taurolidine citrate lock solution (TCLS) against catheter related infections. Materials and Methods: We evaluated records of the 108 patients implanted with 112 TIAPs, which had been performed using heparin solution or TCLS between 2005 and 2013.

Results

Duration of exposure to TIAPs was 17-2051 days (median: 411 days). The primary diagnoses were solid tumours (n = 57), lymphoma (n = 23), haematologic diseases (n = 23), nephrotic syndrome (n = 4), Hirschsprung disease (n = 1). The right external jugular vein was most frequently used vascular access route (72.3%). Mechanical complications were observed in four cases. TIAPs were removed due to remission in 19 cases and infection in 19 cases. Median time from implantation and to the development of infection was 60 days. Heparin solution had been used for care in 33 ports, whereas heparin and TCLS had been used in 79 ports. Based on statistical comparison, use of TCLS was considered to be an important factor for preventing infection (P = 0.03).

Conclusion

We consider that TCLS reduces infection prevalence so TIAPs would be used more extensively and effectively to prevent infections.

Zitieren

APA

Ince, E., Oğuzkurt, P., Temiz, A., Ezer, S. S., Gezer, H. Ö., Yazici, N., & Hiçsönmez, A. (2026). Complications of total implantable access ports and efficacy of Taurolidine-citrate lock solution against catheter-related infections. African Journal of Paediatric Surgery, 11(2), 138-142. https://doi.org/10.67481/ajps.v11i2.492

Vancouver

Ince E, Oğuzkurt P, Temiz A, Ezer SS, Gezer HÖ, Yazici N, et al. Complications of total implantable access ports and efficacy of Taurolidine-citrate lock solution against catheter-related infections. African Journal of Paediatric Surgery. 2026;11(2):138-142. doi:10.67481/ajps.v11i2.492

BibTeX
@article{Ince2026,
  author = {Ince, Emine and Oğuzkurt, Pelin and Temiz, Abdulkerim and Ezer, Semire Serin and Gezer, Hasan Özkan and Yazici, Nalan and Hiçsönmez, Akgün},
  title = {Complications of total implantable access ports and efficacy of Taurolidine-citrate lock solution against catheter-related infections},
  journal = {African Journal of Paediatric Surgery},
  year = {2026},
  volume = {11},
  number = {2},
  pages = {138--142},
  doi = {10.67481/ajps.v11i2.492}
}
Kostenlos starten →