Spatial Radiation Mapping and Shielding Evaluation of a High-Dose-Rate Brachytherapy Bunker during Treatment at Ahmadu Bello University Teaching Hospital, Zaria, Nigeria
Unimaid Journal of Physics and Radiation Studies · 2026
DOI: 10.67365/y007tw ↗Kurz gefasst
Fachartikel in der Zeitschrift Unimaid Journal of Physics and Radiation Studies, 2026. Verfasst von Jacob Mbaye und 2 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
This study evaluated the spatial distribution of radiation levels and shielding performance of a High-Dose-Rate (HDR) brachytherapy Bunker at Ahmadu Bello University Teaching Hospital (ABUTH), Zaria, Nigeria, during treatment. A descriptive cross-sectional radiation survey was conducted using a calibrated RADOS-120 Universal Survey Meter to measure ambient dose rates at 26 selected locations within and around the HDR brachytherapy facility during patient treatment. Measurements were obtained during more than ten treatment sessions using a Cobalt-60 Eckert and Ziegler BEBIG Multi-Source HDR remote after-loading system installed on 16 October 2023 with an activity of 76.79 GBq (2.08 Ci) that had decayed to 54.19 GBq (1.46 Ci) at the time of the study. Three readings were recorded at each location and averaged for analysis. The measured dose rates ranged from 0.11 to 0.27 µSv/h, with the highest mean value recorded at the Treatment room door and the lowest values observed at the patients' waiting Area and nurses' equipment room. Radiation levels generally decreased with increasing distance from the treatment bunker, indicating effective attenuation by the shielding barriers. Based on the highest mean dose rate and an occupancy assumption of 8 hours per day, 5 days per week, and 52 weeks per year, the estimated annual dose was 0.56mSv/year, which is below internationally recommended dose limits. The low radiation levels observed were consistent with the substantial shielding provided by the 85 cm reinforced concrete walls. The findings indicate low ambient radiation levels around the bunker during treatment and provide a baseline for quality assurance and future radiation safety assessments in HDR brachytherapy facilities. Ambient dose-rate measurements alone do not establish regulatory compliance or actual personnel doses.
Zitieren
APA
Mbaye, J., Hassan, M., & Shuaibu, A. S. (2026). Spatial Radiation Mapping and Shielding Evaluation of a High-Dose-Rate Brachytherapy Bunker during Treatment at Ahmadu Bello University Teaching Hospital, Zaria, Nigeria. Unimaid Journal of Physics and Radiation Studies. https://doi.org/10.67365/y007tw
Vancouver
Mbaye J, Hassan M, Shuaibu AS. Spatial Radiation Mapping and Shielding Evaluation of a High-Dose-Rate Brachytherapy Bunker during Treatment at Ahmadu Bello University Teaching Hospital, Zaria, Nigeria. Unimaid Journal of Physics and Radiation Studies. 2026. doi:10.67365/y007tw
BibTeX
@article{Mbaye2026,
author = {Mbaye, Jacob and Hassan, Mujaheed and Shuaibu, Abubakar Saidu},
title = {Spatial Radiation Mapping and Shielding Evaluation of a High-Dose-Rate Brachytherapy Bunker during Treatment at Ahmadu Bello University Teaching Hospital, Zaria, Nigeria},
journal = {Unimaid Journal of Physics and Radiation Studies},
year = {2026},
doi = {10.67365/y007tw}
}