EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validation of International Organisation for Standardisation Protection Levels (ISO PLs) for Respiratory Protective Devices

Nick Baxter, Helen Beattie, Sam Hinchcliffe, Ruby Fort-Persaud

Journal of the International Society for Respiratory Protection · 10.09.2026 · 43

DOI: 10.66828/001c.170173 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 10.09.2026. Verfasst von Nick Baxter und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

There is a range of global performance standards for the different types of respiratory protective devices (RPD). Each type of RPD has a range of assigned protection factors (APFs) which assist with selection. However, these APFs vary between countries. Therefore, there is no global consensus for determining how much protection a certain type of RPD provides to the wearer during use. The International Organisation for Standardisation (ISO) has developed a suite of RPD standards under ‘BS ISO 17420-1:2021 Respiratory protective devices – Performance requirements. Part 1: General’. This describes a new protection class/level (ISO PC/PL) system to allow the performance of all RPD across the globe to be classified. However, this new system has yet to be validated.

Objective

To generate ISO PC/PL validation data for five RPD types and compare with current APF values.

Methods

Total inward leakage testing was undertaken according to the ISO performance and test method standards. Five RPD types (filtering facepiece, half-mask, full-face mask, powered with full-face mask and powered with hood/helmet) were selected for testing. Testing was carried out in two phases, 21 months apart. Tight-fitting RPD was assessed to fit the wearer by passing a fit test.

Results

An ISO PL of 10 was determined for the filtering facepiece, an ISO PL of 30 was determined for the half-mask, an ISO PL of 30 and 250 was determined for the full-face mask, and an ISO PL of 250 and 10 000 was determined for both the powered with full-facemask and hood/helmet.

Conclusion

Lower performing RPD gave similar ISO PL data to the current APF, whereas the higher performing RPD gave a wide range of ISO PL, some much higher than the current APF. Further validation is required.

Zitieren

APA

Baxter, N., Beattie, H., Hinchcliffe, S., & Fort-Persaud, R. (2026). Validation of International Organisation for Standardisation Protection Levels (ISO PLs) for Respiratory Protective Devices. Journal of the International Society for Respiratory Protection, 43. https://doi.org/10.66828/001c.170173

Vancouver

Baxter N, Beattie H, Hinchcliffe S, Fort-Persaud R. Validation of International Organisation for Standardisation Protection Levels (ISO PLs) for Respiratory Protective Devices. Journal of the International Society for Respiratory Protection. 2026;43. doi:10.66828/001c.170173

BibTeX
@article{Baxter2026,
  author = {Baxter, Nick and Beattie, Helen and Hinchcliffe, Sam and Fort-Persaud, Ruby},
  title = {Validation of International Organisation for Standardisation Protection Levels (ISO PLs) for Respiratory Protective Devices},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {2026},
  volume = {43},
  doi = {10.66828/001c.170173}
}
Kostenlos starten →