Background
There is a range of global performance standards for the different types of respiratory protective devices (RPD). Each type of RPD has a range of assigned protection factors (APFs) which assist with selection. However, these APFs vary between countries. Therefore, there is no global consensus for determining how much protection a certain type of RPD provides to the wearer during use. The International Organisation for Standardisation (ISO) has developed a suite of RPD standards under ‘BS ISO 17420-1:2021 Respiratory protective devices – Performance requirements. Part 1: General’. This describes a new protection class/level (ISO PC/PL) system to allow the performance of all RPD across the globe to be classified. However, this new system has yet to be validated.
Objective
To generate ISO PC/PL validation data for five RPD types and compare with current APF values.
Methods
Total inward leakage testing was undertaken according to the ISO performance and test method standards. Five RPD types (filtering facepiece, half-mask, full-face mask, powered with full-face mask and powered with hood/helmet) were selected for testing. Testing was carried out in two phases, 21 months apart. Tight-fitting RPD was assessed to fit the wearer by passing a fit test.
Results
An ISO PL of 10 was determined for the filtering facepiece, an ISO PL of 30 was determined for the half-mask, an ISO PL of 30 and 250 was determined for the full-face mask, and an ISO PL of 250 and 10 000 was determined for both the powered with full-facemask and hood/helmet.
Conclusion
Lower performing RPD gave similar ISO PL data to the current APF, whereas the higher performing RPD gave a wide range of ISO PL, some much higher than the current APF. Further validation is required.
Zitieren
APA
Baxter, N., Beattie, H., Hinchcliffe, S., & Fort-Persaud, R. (2026). Validation of International Organisation for Standardisation Protection Levels (ISO PLs) for Respiratory Protective Devices. Journal of the International Society for Respiratory Protection, 43. https://doi.org/10.66828/001c.170173
Vancouver
Baxter N, Beattie H, Hinchcliffe S, Fort-Persaud R. Validation of International Organisation for Standardisation Protection Levels (ISO PLs) for Respiratory Protective Devices. Journal of the International Society for Respiratory Protection. 2026;43. doi:10.66828/001c.170173
BibTeX
@article{Baxter2026,
author = {Baxter, Nick and Beattie, Helen and Hinchcliffe, Sam and Fort-Persaud, Ruby},
title = {Validation of International Organisation for Standardisation Protection Levels (ISO PLs) for Respiratory Protective Devices},
journal = {Journal of the International Society for Respiratory Protection},
year = {2026},
volume = {43},
doi = {10.66828/001c.170173}
}
EUVIMED