Effects of Full Face-Piece Respirator Design on Detection of Peripherally Located Stimuli

David M. Caretti

Journal of the International Society for Respiratory Protection · 1996

DOI: 10.66828/001c.168340 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, 1996. Verfasst von David M. Caretti. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reaction time for detection of light signals distributed throughout the visual field was assessed during wear of a dual lens, face-mounted air-purifying canister mask (DLFM) and a single lens, remotely placed air-purifying canister mask (SLR) to determine the effects of each design on wearer detection sensitivity. Mask performance ratings for radial limits of field of view were also assessed for each condition. Although both the DLFM and SLR respirators resulted in a decrease in visual field performance ratings, the magnitude of detriments was significantly greater with the DLFM mask. Response time for signal detection increased with greater peripheralization of light locations for DLFM, SLR, and control conditions. However, mean reaction time during wear of the DLFM respirator was significantly greater than reaction time during wear of the SLR mask for peripheral rings positioned at 38°, 64°, and 90° from the central line of sight. Wear of the DLFM mask also resulted in the worst performance for stimuli located superior and inferior to the horizontal axis of view. These results clearly indicate the detrimental effects of a dual lens, facemounted air-purifying canister respirator design on signal detection sensitivity.

Zitieren

APA

Caretti, D. M. (1996). Effects of Full Face-Piece Respirator Design on Detection of Peripherally Located Stimuli. Journal of the International Society for Respiratory Protection. https://doi.org/10.66828/001c.168340

Vancouver

Caretti DM. Effects of Full Face-Piece Respirator Design on Detection of Peripherally Located Stimuli. Journal of the International Society for Respiratory Protection. 1996. doi:10.66828/001c.168340

BibTeX
@article{Caretti1996,
  author = {Caretti, David M.},
  title = {Effects of Full Face-Piece Respirator Design on Detection of Peripherally Located Stimuli},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {1996},
  doi = {10.66828/001c.168340}
}
Kostenlos starten →