Comparison of Two Newly Developed Methods for Fit Testing N95 Respirators

Ziqing Zhuang, Christopher C. Coffey, Donald L. Campbell, Warren R. Myers

Journal of the International Society for Respiratory Protection · 1998

DOI: 10.66828/001c.168225 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, 1998. Verfasst von Ziqing Zhuang und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The only 30 CFR 11 filters which could be used in quantitative fit testing were high-efficiency particulate aerosol (HEPA) filters. These were the only filters which did not have significant penetration of the aerosols used in quantitative fit tests. However, the new National Institute for Occupational Safety and Health (NIOSH) respirator certification regulations (42 CFR Part 84) require all particulate respirators to be tested with an aerosol in the most penetrating size range and to have a minimum filter efficiency of 95%. As a result of the improved filter performance assured by these new regulations, a question has arisen regarding whether N95 respirators (one of the new classes of particulate respirators) could be quantitatively fit tested. In response, NIOSH and TSI Incorporated researchers developed a method for fit testing N95 filteringfacepiece respirators using the PortaCount Plus™ with a filter ratio test clamp to measure filter penetration. Meanwhile, TSI also developed a new accessory (the N95-COMPANION™ for the PortaCount Plus™) to fit test N95 respirators. The purpose of this study was to determine how well the fit factors from these two methods correlate. The facepiece fit of each respirator model was measured on a panel of 25 subjects with varying face sizes. A “standard” PortaCount Plus™ test was conducted for each subject/respirator combination. However, since N95 filter media can have significant penetration of ambient particles, the “standard” PortaCount Plus™ fit test measured total penetration (i.e., filter penetration and face seal leakage) and not just face seal leakage. Filter penetration was measured on each respirator using the PortaCount Plus™ with the clamp, and an adjusted fit factor computed. Immediately after the “standard” PortaCount Plus™ test, a fit test for each subject/respirator combination was conducted using the N95-COMPANION™ in conjunction with the PortaCount Plus™ without the respirator being redonned. Log-transformed Companion fit factors and log-transformed adjusted fit factors were strongly correlated (R2 ranged from 0.66 to 0.92 depending on the regression models). The slope of the regression equation for one respirator model was significantly different from the slopes for the other four respirator models. The authors concluded that both methods provided comparable fit factors for each respirator/subject combination. Future studies should characterize the ambient particle size distribution inside the N95 filtering-facepiece respirators.

Zitieren

APA

Zhuang, Z., Coffey, C. C., Campbell, D. L., & Myers, W. R. (1998). Comparison of Two Newly Developed Methods for Fit Testing N95 Respirators. Journal of the International Society for Respiratory Protection. https://doi.org/10.66828/001c.168225

Vancouver

Zhuang Z, Coffey CC, Campbell DL, Myers WR. Comparison of Two Newly Developed Methods for Fit Testing N95 Respirators. Journal of the International Society for Respiratory Protection. 1998. doi:10.66828/001c.168225

BibTeX
@article{Zhuang1998,
  author = {Zhuang, Ziqing and Coffey, Christopher C. and Campbell, Donald L. and Myers, Warren R.},
  title = {Comparison of Two Newly Developed Methods for Fit Testing N95 Respirators},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {1998},
  doi = {10.66828/001c.168225}
}
Kostenlos starten →