Accelerated Aging of Surgical N95 Filtering Facepiece Respirator (FFR) Straps: Pressure Reactor Vs. Oven Aging Methods
Journal of the International Society for Respiratory Protection · 01.07.2025 · 42 (1)
DOI: 10.66828/001c.167274 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 01.07.2025. Verfasst von K Zin Htut und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Personal Protective Equipment (PPE), such as surgical N95 filtering facepiece respirators (FFR), undergoes oxidative degradation during extended storage, potentially compromising its effectiveness. This study aimed to develop a screening test for oxidative degradation of surgical N95 FFR straps. Straps from three respirator models were aged using traditional oven aging at 70 °C under ambient air or in a pressure reactor at room temperature under oxygen pressures of 20 or 40 bar. Characterization using tensile tests and Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) spectroscopy showed that pressure reactor aging significantly accelerated degradation more than traditional oven aging. Straps maintained stability up to a critical oxidative threshold, beyond which significant deterioration occurred. ATR-FTIR analysis underscored the complexity of assessing oxidative degradation due to variable chemical composition across models. This research highlights that mechanical properties, particularly modulus, can serve as reliable indicators of long-term stability and performance, offering a more streamlined and direct approach for future PPE evaluations. The pressure reactor aging at room temperature not only expedites degradation assessment but also potentially more closely mimics real-time aging on the shelf, which could simplify the design of future studies and support the development of standardized oxidative degradation screening tests for various types of PPE.
Zitieren
APA
Htut, K. Z., & Jain*, T. (2025). Accelerated Aging of Surgical N95 Filtering Facepiece Respirator (FFR) Straps: Pressure Reactor Vs. Oven Aging Methods. Journal of the International Society for Respiratory Protection, 42(1). https://doi.org/10.66828/001c.167274
Vancouver
Htut KZ, Jain* T. Accelerated Aging of Surgical N95 Filtering Facepiece Respirator (FFR) Straps: Pressure Reactor Vs. Oven Aging Methods. Journal of the International Society for Respiratory Protection. 2025;42(1). doi:10.66828/001c.167274
BibTeX
@article{Htut2025,
author = {Htut, K Zin and Jain*, Tanmay},
title = {Accelerated Aging of Surgical N95 Filtering Facepiece Respirator (FFR) Straps: Pressure Reactor Vs. Oven Aging Methods},
journal = {Journal of the International Society for Respiratory Protection},
year = {2025},
volume = {42},
number = {1},
doi = {10.66828/001c.167274}
}