EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Nanoparticle Penetration Through NIOSH-approved N95 Filtering-facepiece Respirators

Samy Rengasamy*, Russel Verbofsky, William P. King, Ronald E. Shaffer

Journal of the International Society for Respiratory Protection · 2007

DOI: 10.66828/001c.167235 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, 2007. Verfasst von Samy Rengasamy* und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to compare NaCl particle penetration through five NIOSH-approved N95 filtering-facepiece respirator models using two test methods. Data from a polydisperse aerosol challenge similar to the NIOSH respirator certification test was compared to data collected using monodisperse aerosols ranging from 20 nm to 400 nm. The average initial penetration levels from the polydisperse aerosol tests ranged from 0.61% to 1.24% for the five respirator models tested. Monodisperse aerosol penetrations behaved according to single fiber filtration theory. The most penetrating particle size was found to be near 40 nm. Average penetration of 40 nm particles was found to exceed 5% for two respirator models, but was not statistically significant compared to the 5% criteria for class “95” respirators used by NIOSH with the certification test. The rank ordering of the filtration performances of the five respirator models was consistent between the two test methods.

Zitieren

APA

Rengasamy*, S., Verbofsky, R., King, W. P., & Shaffer, R. E. (2007). Nanoparticle Penetration Through NIOSH-approved N95 Filtering-facepiece Respirators. Journal of the International Society for Respiratory Protection. https://doi.org/10.66828/001c.167235

Vancouver

Rengasamy* S, Verbofsky R, King WP, Shaffer RE. Nanoparticle Penetration Through NIOSH-approved N95 Filtering-facepiece Respirators. Journal of the International Society for Respiratory Protection. 2007. doi:10.66828/001c.167235

BibTeX
@article{Rengasamy2007,
  author = {Rengasamy*, Samy and Verbofsky, Russel and King, William P. and Shaffer, Ronald E.},
  title = {Nanoparticle Penetration Through NIOSH-approved N95 Filtering-facepiece Respirators},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {2007},
  doi = {10.66828/001c.167235}
}
Kostenlos starten →