EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance of an N95 Filtering Facepiece Respirator in a Grinding Operation

Larry Janssen*, Jeanne Bidwell, Nicole McCullough, Thomas J. Nelson

Journal of the International Society for Respiratory Protection · 01.07.2007 · 24 (1-2)

DOI: 10.66828/001c.167231 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 01.07.2007. Verfasst von Larry Janssen* und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the workplace performance of an N95 filtering facepiece air purifying respirator in the grinding room of an aluminum and magnesium alloy foundry. Air samples were collected inside and outside the respirators worn by workers who were properly trained and qualitatively fit tested. Several pairs of samples were collected on five workers on four consecutive days, resulting in 56 valid sample sets. The samples were analyzed for aluminum and magnesium. While the ambient atmosphere had adequate contaminant concentrations to measure facepiece contaminant penetration at the levels expected for half facepiece respirators, many of t he in-facepiece samples did not have detectible aluminum or magnesium. A workplace protection factor (WPF) estimate was calculated for each sample pair, the values rounded down to two significant figures and a rank and percentile function performed. Individual WPF estimates ranged from 24 to 9,100. The 50th percentile value was greater than 1,100 and the lower 5th percentile was greater than 71. It is believed that this level of respirator performance was due to the stationary nature of the work and relatively low work rate. This respirator’s performance clearly supports the assigned protection factor of 10 typically used for half facepiece respirators. However, these results do not suggest that the assigned protection factor should be increased.

Zitieren

APA

Janssen*, L., Bidwell, J., McCullough, N., & Nelson, T. J. (2007). Performance of an N95 Filtering Facepiece Respirator in a Grinding Operation. Journal of the International Society for Respiratory Protection, 24(1-2). https://doi.org/10.66828/001c.167231

Vancouver

Janssen* L, Bidwell J, McCullough N, Nelson TJ. Performance of an N95 Filtering Facepiece Respirator in a Grinding Operation. Journal of the International Society for Respiratory Protection. 2007;24(1-2). doi:10.66828/001c.167231

BibTeX
@article{Janssen2007,
  author = {Janssen*, Larry and Bidwell, Jeanne and McCullough, Nicole and Nelson, Thomas J.},
  title = {Performance of an N95 Filtering Facepiece Respirator in a Grinding Operation},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {2007},
  volume = {24},
  number = {1-2},
  doi = {10.66828/001c.167231}
}
Kostenlos starten →