An Innovative Approach to Evaluating Protection Level of Tight-Fitting PAPRs When Face Seal Is Compromised
Journal of the International Society for Respiratory Protection · 01.01.2023 · 39 (2)
DOI: 10.66828/001c.166372 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 01.01.2023. Verfasst von Dmitri Kazakov1* und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Few studies have been done to investigate the ability of tight-fitting Powered Air Purifying Respirators (PAPRs) to compensate for face seal leaks, and this project developed an innovative approach to evaluating the protection level of PAPRs when the face seal is compromised. For this study, a cross sectional area of seal leaks versus a reduction in protection factor was used to evaluate the potential effect of a simulated leak on PAPRs during over breathing whilst exercising on a bicycle. It was found that the ability of PAPRs to maintain positive pressure cannot be assessed by constant-flow measurement or by the sinusoidal profile of a breathing machine, however it can be assessed by collecting pressure data from inside the mask during TIL human exercise and analysing the cumulative “weight” of the negative-pressure events. Furthermore, the pressure fluctuation representing Work of Breathing does not show as much variation as the variation of the mask leakage, and some PAPRs have even larger pressure variation in comparison to the negative-pressure masks. It was concluded that the PAPRs tested are not so much breathing-assisting respirators as they are mask-leak compensation devices. PAPRs can provide additional face seal protection to the wearer in the event of mask leakage. Some PAPRs significantly outperformed the Air Purifying Respirators (APRs) (by 1900 times) whilst others minimally exceeded the protection of APRs (by 2 times) with a greater pressure variation (caused by the breathing resistance due to motor/impeller inertia) during the breathing cycles at high workloads.
Zitieren
APA
Kazakov1*, D., Powe, G., & Zhu, J. (2023). An Innovative Approach to Evaluating Protection Level of Tight-Fitting PAPRs When Face Seal Is Compromised. Journal of the International Society for Respiratory Protection, 39(2). https://doi.org/10.66828/001c.166372
Vancouver
Kazakov1* D, Powe G, Zhu J. An Innovative Approach to Evaluating Protection Level of Tight-Fitting PAPRs When Face Seal Is Compromised. Journal of the International Society for Respiratory Protection. 2023;39(2). doi:10.66828/001c.166372
BibTeX
@article{Kazakov2023,
author = {Kazakov1*, Dmitri and Powe, Graham and Zhu, Jintuo},
title = {An Innovative Approach to Evaluating Protection Level of Tight-Fitting PAPRs When Face Seal Is Compromised},
journal = {Journal of the International Society for Respiratory Protection},
year = {2023},
volume = {39},
number = {2},
doi = {10.66828/001c.166372}
}
EUVIMED