EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Informing the Public’s Unassisted Use of Diverse Facepieces Designed to Form a Seal: Quantitative, Comparative Testing Using the ASTM F3502 Leakage Assessment Test Method

Chris Baglin, Paul Baglin, Axel Bawor, Fiona Henriquez, William Mackay

Journal of the International Society for Respiratory Protection · 31.12.2025 · 42 (2)

DOI: 10.66828/001c.160200 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 31.12.2025. Verfasst von Chris Baglin und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

A National Academies of Science study details the need for respiratory protection for the public. However, assistance with facepiece selection, fit, and use, is rarely available in the community resulting in suboptimal use of facepieces. This study evaluated filtering facepiece respirators (FFR) and a barrier face covering in unassisted conditions.

Objective

This study compares the effectiveness of diverse facepieces in blocking aerosols during unassisted use, by employing the ASTM F3502 Leakage Assessment, which adopts the ASTM F3407 fit capability test method with modifications designed to model unassisted donning.

Methods

An ASTM F3502-2021 Standard Specification for Barrier Face Coverings Leakage Assessment was conducted with a TSI Portacount 8048, for facepiece models worn by participants given no coaching or assistance. The F3502 method follows ASTM F3407 Standard Test Method for Respirator Fit Capability but with modifications to account for unassisted facepiece use outside of a respiratory protection program. The performance target, a leakage ratio of 10, would reflect 90% blocking of particles. Two FFR models and a reusable Barrier Face Covering were studied on 59 participants.

Results

The facepieces performed above the target performance level, indicating, on average, more than 90% protection, with one FFR achieving 94% and the reusable barrier face covering achieving 93%.

Conclusion

Disposable respirators and reusable face coverings can be compared quantitatively using the Leakage Assessment test method in ASTM F3502, which provides a critical tool for understanding and improving unassisted use of facepieces by the public.

Zitieren

APA

Baglin, C., Baglin, P., Bawor, A., Henriquez, F., & Mackay, W. (2025). Informing the Public’s Unassisted Use of Diverse Facepieces Designed to Form a Seal: Quantitative, Comparative Testing Using the ASTM F3502 Leakage Assessment Test Method. Journal of the International Society for Respiratory Protection, 42(2). https://doi.org/10.66828/001c.160200

Vancouver

Baglin C, Baglin P, Bawor A, Henriquez F, Mackay W. Informing the Public’s Unassisted Use of Diverse Facepieces Designed to Form a Seal: Quantitative, Comparative Testing Using the ASTM F3502 Leakage Assessment Test Method. Journal of the International Society for Respiratory Protection. 2025;42(2). doi:10.66828/001c.160200

BibTeX
@article{Baglin2025,
  author = {Baglin, Chris and Baglin, Paul and Bawor, Axel and Henriquez, Fiona and Mackay, William},
  title = {Informing the Public’s Unassisted Use of Diverse Facepieces Designed to Form a Seal: Quantitative, Comparative Testing Using the ASTM F3502 Leakage Assessment Test Method},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {2025},
  volume = {42},
  number = {2},
  doi = {10.66828/001c.160200}
}
Kostenlos starten →