EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC-ND 4.0

Case Report: Novel Use of a Variable Neutral-Density Filter in Vision Therapy for Exotropia with Deep Suppression

Chak Yin, Charles Li

Clinical Insights in Eyecare · 2026

DOI: 10.66574/001c.167573 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Clinical Insights in Eyecare, 2026. Verfasst von Chak Yin und 1 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Suppression is a common sensory adaptation in exotropia and may limit the recovery of fusion during vision therapy. However, simple clinical methods for grading suppression continuously and modifying interocular suppression during office-based vision therapy are limited. This case report describes the novel use of a variable neutral-density filter as both a diagnostic and therapeutic adjunct in the management of exotropia. Case Report An 8-year-old girl presented with worsening left exotropia. Examination showed 20/20 visual acuity in each eye, constant left exotropia measuring 50∆ at distance and 55∆ at near, and left eye suppression on Worth 4-dot testing across all distances and lighting conditions. A variable neutral-density filter was placed in front of the dominant right eye to reduce luminance in a graded manner. At an optical density of 0.6 log units, pathological diplopia was elicited at near with Worth 4-dot testing, and the patient achieved a near point of convergence of 20 cm. The filter was then incorporated into office-based vision therapy to facilitate sensory rebalancing, reduce suppression, and make earlier convergence training possible. Over 12 sessions, binocular stability was achieved without luminance attenuation. The final findings show well-controlled exodeviation, elimination of suppression on Worth 4-dot testing, recovery of global and local stereopsis, and improved fusional vergence reserves.

Conclusion

A variable neutral-density filter may be a practical, low-cost adjunct for treating deep suppression in exotropia. It allows continuous suppression grading, reduces reliance on multiple therapy tools, and enables earlier convergence training in patients with significant suppression.

Zitieren

APA

Yin, C., & Li, C. (2026). Case Report: Novel Use of a Variable Neutral-Density Filter in Vision Therapy for Exotropia with Deep Suppression. Clinical Insights in Eyecare. https://doi.org/10.66574/001c.167573

Vancouver

Yin C, Li C. Case Report: Novel Use of a Variable Neutral-Density Filter in Vision Therapy for Exotropia with Deep Suppression. Clinical Insights in Eyecare. 2026. doi:10.66574/001c.167573

BibTeX
@article{Yin2026,
  author = {Yin, Chak and Li, Charles},
  title = {Case Report: Novel Use of a Variable Neutral-Density Filter in Vision Therapy for Exotropia with Deep Suppression},
  journal = {Clinical Insights in Eyecare},
  year = {2026},
  doi = {10.66574/001c.167573}
}
Kostenlos starten →