Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT
Revista Dominicana de Gastroenterología · 15.01.2026 · 1 (01) · 16-23
DOI: 10.66464/0x2v7z74 ↗Kurz gefasst
Fachartikel in der Zeitschrift Revista Dominicana de Gastroenterología, online erschienen am 15.01.2026. Verfasst von Carlota Cabrer P. und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The effectiveness of screening colonoscopy depends on meeting quality indicators associated with a lower risk of colorectal cancer, mortality, and post-colonoscopy colorectal cancer.
Objective
To evaluate six basic quality indicators and immediate complications in screening colonoscopies performed at the Gastroenterology Unit of CEDIMAT (September–December 2024).
Methods
Observational, cross-sectional, retrospective, descriptive study. We included 498 adult screening colonoscopies performed at the Gastroenterology Unit of CEDIMAT (September–December 2024). Indicators were extracted from electronic records and measured at collective and individual levels using Olympus 180 systems (white light with on-demand NBI). Reporting followed STROBE, and descriptive statistics were used.
Results
N=498; 64% women. Mean Boston score was 7.88; 87.95% had Boston ≥6 and 84% also achieved Boston ≥2 in each segment (adequate preparation). Cecal intubation rate was 99% (all endoscopists ≥95%). Mean withdrawal time in normal colonoscopies was 9 min 56 s; 69% achieved ≥6 min and 61% ≥8 min. Adenoma detection rate was 25% (individual range 10.91–60%), serrated lesion detection rate 0.4%, and polyp detection rate 37% (individual range 20–80%). No immediate complications were recorded.
Conclusion
Quality indicators approached international benchmarks; improvement opportunities remain in the proportion of withdrawal times ≥6–8 minutes and in adenoma and serrated lesion detection rates. No immediate adverse events were recorded, suggesting a favorable safety profile.
Zitieren
APA
P., C. C., O., L. M., B., A. D. L. S., P., F. C., & R., E. B. (2026). Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT. Revista Dominicana de Gastroenterología, 1(01), 16-23. https://doi.org/10.66464/0x2v7z74
Vancouver
P. CC, O. LM, B. ADLS, P. FC, R. EB. Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT. Revista Dominicana de Gastroenterología. 2026;1(01):16-23. doi:10.66464/0x2v7z74
BibTeX
@article{P2026,
author = {P., Carlota Cabrer and O., Lisbeth Martínez and B., Alma De los Santos and P., Fernando Contreras and R., Eduardo Bon},
title = {Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT},
journal = {Revista Dominicana de Gastroenterología},
year = {2026},
volume = {1},
number = {01},
pages = {16--23},
doi = {10.66464/0x2v7z74}
}
EUVIMED