EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT

Carlota Cabrer P., Lisbeth Martínez O., Alma De los Santos B., Fernando Contreras P., Eduardo Bon R.

Revista Dominicana de Gastroenterología · 15.01.2026 · 1 (01) · 16-23

DOI: 10.66464/0x2v7z74 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Dominicana de Gastroenterología, online erschienen am 15.01.2026. Verfasst von Carlota Cabrer P. und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The effectiveness of screening colonoscopy depends on meeting quality indicators associated with a lower risk of colorectal cancer, mortality, and post-colonoscopy colorectal cancer.

Objective

To evaluate six basic quality indicators and immediate complications in screening colonoscopies performed at the Gastroenterology Unit of CEDIMAT (September–December 2024).

Methods

Observational, cross-sectional, retrospective, descriptive study. We included 498 adult screening colonoscopies performed at the Gastroenterology Unit of CEDIMAT (September–December 2024). Indicators were extracted from electronic records and measured at collective and individual levels using Olympus 180 systems (white light with on-demand NBI). Reporting followed STROBE, and descriptive statistics were used.

Results

N=498; 64% women. Mean Boston score was 7.88; 87.95% had Boston ≥6 and 84% also achieved Boston ≥2 in each segment (adequate preparation). Cecal intubation rate was 99% (all endoscopists ≥95%). Mean withdrawal time in normal colonoscopies was 9 min 56 s; 69% achieved ≥6 min and 61% ≥8 min. Adenoma detection rate was 25% (individual range 10.91–60%), serrated lesion detection rate 0.4%, and polyp detection rate 37% (individual range 20–80%). No immediate complications were recorded.

Conclusion

Quality indicators approached international benchmarks; improvement opportunities remain in the proportion of withdrawal times ≥6–8 minutes and in adenoma and serrated lesion detection rates. No immediate adverse events were recorded, suggesting a favorable safety profile.

Zitieren

APA

P., C. C., O., L. M., B., A. D. L. S., P., F. C., & R., E. B. (2026). Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT. Revista Dominicana de Gastroenterología, 1(01), 16-23. https://doi.org/10.66464/0x2v7z74

Vancouver

P. CC, O. LM, B. ADLS, P. FC, R. EB. Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT. Revista Dominicana de Gastroenterología. 2026;1(01):16-23. doi:10.66464/0x2v7z74

BibTeX
@article{P2026,
  author = {P., Carlota Cabrer and O., Lisbeth Martínez and B., Alma De los Santos and P., Fernando Contreras and R., Eduardo Bon},
  title = {Análisis de 6 parámetros de calidad de las colonoscopias detamizaje realizadas en la Unidad de Gastroenterología de CEDIMAT},
  journal = {Revista Dominicana de Gastroenterología},
  year = {2026},
  volume = {1},
  number = {01},
  pages = {16--23},
  doi = {10.66464/0x2v7z74}
}
Kostenlos starten →