A Comparative Evaluation of LSTM and Bidirectional LSTM Architectures for Nitrogen Oxide Forecasting in Air Quality Monitoring
Engineering Systems and Intelligent Technologies (ESIT) · 29.06.2026 · 3 (1) · 1-12
DOI: 10.66279/9c0e5874 ↗Kurz gefasst
Fachartikel in der Zeitschrift Engineering Systems and Intelligent Technologies (ESIT), online erschienen am 29.06.2026. Verfasst von Mohamed Hassan Essai Ali und 2 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Reliable, real-time monitoring of nitrogen oxides (NOx ) is essential for air quality management, yet conventional monitoring networks are limited by sparse spatial coverage and inconsistent predictive reliability. This study compares Long Short-Term Memory (LSTM) and Bidirectional LSTM (BiLSTM) networks for forecasting NOx concentrations using the UCI Air Quality Dataset. To assess these architectures rigorously, we benchmark them against a persistence forecast and an ARIMA model, apply expanding-window temporal cross-validation to guard against data leakage, and test the significance of any performance gap with the Diebold–Mariano statistic. Both recurrent architectures attain high accuracy (R2 > 0.999), with BiLSTM showing a marginally higher mean R2 (0.99977 versus 0.99972 for LSTM); however, the Diebold–Mariano test indicates that this difference is not statistically significant (p = 0.384), so the two architectures should be regarded as practically equivalent for this task. Both deep learning models substantially outperform the statistical baselines, most notably ARIMA (R2 = 0.854), which supports the value of recurrent architectures for NOx forecasting while also underscoring the importance of baseline comparison and leakage-aware validation in this line of work.
Zitieren
APA
Ali, M. H. E., Ali, M. M., & Mahran, G. M. A. (2026). A Comparative Evaluation of LSTM and Bidirectional LSTM Architectures for Nitrogen Oxide Forecasting in Air Quality Monitoring. Engineering Systems and Intelligent Technologies (ESIT), 3(1), 1-12. https://doi.org/10.66279/9c0e5874
Vancouver
Ali MHE, Ali MM, Mahran GMA. A Comparative Evaluation of LSTM and Bidirectional LSTM Architectures for Nitrogen Oxide Forecasting in Air Quality Monitoring. Engineering Systems and Intelligent Technologies (ESIT). 2026;3(1):1-12. doi:10.66279/9c0e5874
BibTeX
@article{Ali2026,
author = {Ali, Mohamed Hassan Essai and Ali, Mohamed M. and Mahran, Gamal M. A},
title = {A Comparative Evaluation of LSTM and Bidirectional LSTM Architectures for Nitrogen Oxide Forecasting in Air Quality Monitoring},
journal = {Engineering Systems and Intelligent Technologies (ESIT)},
year = {2026},
volume = {3},
number = {1},
pages = {1--12},
doi = {10.66279/9c0e5874}
}
EUVIMED