EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A PARAMETRIC STUDY FOR AIR INJECTION CORRELATIONS IN HELICAL COIL TUBE HEAT EXCHANGERS

Jameel Al-Naffakh, Mohammed Al-Qassab, Israa Jafar

Journal of Science and Engineering Applications · 30.09.2024 · 6 (1)

DOI: 10.66262/jsea.10018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Science and Engineering Applications, online erschienen am 30.09.2024. Verfasst von Jameel Al-Naffakh und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the effects of air injection on heat transfer performance in helical coil tube heat exchangers. Experiments were conducted varying air injection rates (0-50 L/min), injection locations (0%, 33%, 66% of coil length), coil diameters (300 mm, 450 mm), and water flow rates (0.1-0.5 kg/s). Results show significant heat transfer enhancement with air injection, achieving a maximum Nusselt number increase of 84.7% (±4.4%) at 50 L/min air injection. The optimal configuration, balancing heat transfer enhancement and pressure drop, occurred at 30 L/min air injection, 33% injection location, and 300 mm coil diameter, yielding a 62.2% (±3.8%) increase in Nusselt number and a thermal performance factor of 1.32. Air injection efficacy was inversely proportional to water flow rate, with the thermal performance factor decreasing from 1.45 to 1.18 as water flow increased from 0.1 to 0.5 kg/s. Novel correlations for Nusselt number and friction factor were developed, valid for Reynolds numbers 5,00050,000 and Prandtl numbers 3.5-6.5, with mean absolute errors of 7.2% and 8.5% respectively. For a 10 kW heat duty, the optimized air-injected system required 38.3% less heat transfer area compared to a conventional helical coil heat exchanger, at the cost of 34.9% higher pumping power. These findings provide valuable insights for designing and optimizing air-injected helical coil heat exchangers, potentially improving energy efficiency in various industrial applications.

Zitieren

APA

Al-Naffakh, J., Al-Qassab, M., & Jafar, I. (2024). A PARAMETRIC STUDY FOR AIR INJECTION CORRELATIONS IN HELICAL COIL TUBE HEAT EXCHANGERS. Journal of Science and Engineering Applications, 6(1). https://doi.org/10.66262/jsea.10018

Vancouver

Al-Naffakh J, Al-Qassab M, Jafar I. A PARAMETRIC STUDY FOR AIR INJECTION CORRELATIONS IN HELICAL COIL TUBE HEAT EXCHANGERS. Journal of Science and Engineering Applications. 2024;6(1). doi:10.66262/jsea.10018

BibTeX
@article{AlNaffakh2024,
  author = {Al-Naffakh, Jameel and Al-Qassab, Mohammed and Jafar, Israa},
  title = {A PARAMETRIC STUDY FOR AIR INJECTION CORRELATIONS IN HELICAL COIL TUBE HEAT EXCHANGERS},
  journal = {Journal of Science and Engineering Applications},
  year = {2024},
  volume = {6},
  number = {1},
  doi = {10.66262/jsea.10018}
}
Kostenlos starten →