EUVIMEDEUVIMED entdecken
LeitlinieOpen Access · CC BY 4.0

Conformance Verification of Healthcare Application Code Against Clinical Guidelines: A Case Study of Blood Pressure Classification

Alaba Bolaji Ojediran

InfoScience Trends · 10.11.2026 · 3 (14) · 37-52

DOI: 10.66224/ist.202603.14.03 ↗

Kurz gefasst

Leitlinie in der Zeitschrift InfoScience Trends, online erschienen am 10.11.2026. Verfasst von Alaba Bolaji Ojediran. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Healthcare applications increasingly implement clinical guidelines as software-based decision rules. However, validation of measurement accuracy does not establish whether the implemented classification logic conforms to the corresponding clinical guideline. This study evaluated whether exhaustive conformance verification can identify discrepancies between healthcare application code and a named clinical specification. The 2023 European Society of Hypertension (ESH) guideline was formalized as a deterministic reference oracle for blood pressure classification. An exhaustive integer input space comprising systolic blood pressure values from 60 to 260 mmHg and diastolic blood pressure values from 40 to 160 mmHg was generated, yielding 24,321 ordered input pairs. Fifty-seven open-source blood pressure classification applications were evaluated against the reference oracle. Binary hypertensive status and, where applicable, multi-category classification were assessed independently. Disagreements were traced to the corresponding decision branches and characterized according to their structural pattern and clinical direction. All 57 applications reproduced the binary ESH hypertensive/non-hypertensive decision across the complete input space, resulting in 100.000% sensitivity, specificity, and accuracy. Category-level analysis was possible for 41 applications. Fifteen applications achieved ≥99.9% conformance, 10 achieved 80–99.9% conformance, and 16 achieved

Zitieren

APA

Ojediran, A. B. (2026). Conformance Verification of Healthcare Application Code Against Clinical Guidelines: A Case Study of Blood Pressure Classification. InfoScience Trends, 3(14), 37-52. https://doi.org/10.66224/ist.202603.14.03

Vancouver

Ojediran AB. Conformance Verification of Healthcare Application Code Against Clinical Guidelines: A Case Study of Blood Pressure Classification. InfoScience Trends. 2026;3(14):37-52. doi:10.66224/ist.202603.14.03

BibTeX
@article{Ojediran2026,
  author = {Ojediran, Alaba Bolaji},
  title = {Conformance Verification of Healthcare Application Code Against Clinical Guidelines: A Case Study of Blood Pressure Classification},
  journal = {InfoScience Trends},
  year = {2026},
  volume = {3},
  number = {14},
  pages = {37--52},
  doi = {10.66224/ist.202603.14.03}
}
Kostenlos starten →