EUVIMEDEUVIMED entdecken
Crossref

Comparison of dosimetric parameters in radiotherapy plans for gastric cancer between two accelerators

Y. Tian, X. Peng, L. Yang, H. Liu

International Journal of Radiation Research · 01.01.2026 · 24 (1) · 283-287

DOI: 10.66224/ijrr.24.1.42 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Radiation Research, online erschienen am 01.01.2026. Verfasst von Y. Tian und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study compares treatment plans for gastric cancer patients generated using the Varian IX linear accelerator (linac) and the uRT - Linac 506C. Materials and Methods: A retrospective analysis was performed on ten gastric cancer patients. Treatment plans were initially created using Varian Eclipse v13.5 treatment planning system (TPS) and uRT - TPS for intensity - modulated radiation therapy (IMRT), respectively; all plans were developed by an experienced physicist and determined to be clinically acceptable. Dosimetric parameters were compared for the planning target volume (PTV) and organs at risk (OARs), including the conformity index (CI), homogeneity index (HI), and monitor unit (MU) efficiency. The delivery accuracy of both accelerator systems was assessed using gamma index analysis.

Results

Results indicated that the uRT - Linac 506C provided superior dose conformity and target volume coverage compared to the Varian IX linac, as evidenced by a higher V45/% parameter for the uRT - Linac 506C. For the left kidney, the Varian IX linac had a significantly lower maximum dose (Dmax); however, its mean dose (Dmean), V10, and V20 were significantly higher than those of the uRT - Linac 506C. Similar trends were observed for the right kidney and liver, where the Varian IX linac exhibited significantly higher doses and volumes for specific parameters.

Conclusion

In conclusion, both linacs can achieve clinical requirements for gastric cancer radiotherapy; however, the uRT - Linac 506C demonstrated improved dose conformity and target coverage in this study. Further research is warranted to validate these findings and investigate potential clinical implications

Zitieren

APA

Tian, Y., Peng, X., Yang, L., & Liu, H. (2026). Comparison of dosimetric parameters in radiotherapy plans for gastric cancer between two accelerators. International Journal of Radiation Research, 24(1), 283-287. https://doi.org/10.66224/ijrr.24.1.42

Vancouver

Tian Y, Peng X, Yang L, Liu H. Comparison of dosimetric parameters in radiotherapy plans for gastric cancer between two accelerators. International Journal of Radiation Research. 2026;24(1):283-287. doi:10.66224/ijrr.24.1.42

BibTeX
@article{Tian2026,
  author = {Tian, Y. and Peng, X. and Yang, L. and Liu, H.},
  title = {Comparison of dosimetric parameters in radiotherapy plans for gastric cancer between two accelerators},
  journal = {International Journal of Radiation Research},
  year = {2026},
  volume = {24},
  number = {1},
  pages = {283--287},
  doi = {10.66224/ijrr.24.1.42}
}