Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm
Asian Research Journal of Information Technology · 2026 · 3 (3) · 27-38
DOI: 10.66206/eduheart.arjit.3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asian Research Journal of Information Technology, 2026. Verfasst von Dhane Kian Hellie und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Overloading in public utility buses remains a persistent transportation safety and regulatory problem, particularly in urban environments, where monitoring is often conducted through manual inspection. This study developed and evaluated a non-contact overloading detection system for public utility buses using the YOLOv8 object detection algorithm, Raspberry Pi 4, camera module, GPS, and real-time alert transmission. The study employed a descriptive-developmental quantitative design and Agile software development methodology. Fifty respondents participated in the evaluation, consisting of 44 passengers and 6 authorities. System performance was assessed through controlled trials, ISO/IEC 25010-based survey questionnaires, and object detection metrics, including precision, recall, and mean average precision (mAP). Test trials showed detection accuracies ranging from 67% to 82%, with one case of over-detection. Real-time processing achieved an average speed of 0.04 to 0.09 seconds per frame. Survey-based evaluation indicated high acceptance across hardware detection (overall mean = 4.40), alert system performance (overall mean = 4.41), and real-world system performance (overall mean = 4.37). ISO/IEC 25010 evaluation also showed strong results in usability (4.46), security (4.44), maintainability (4.44), reliability (4.37), efficiency (4.37), and functionality (4.19). YOLOv8 performance metrics reported precision = 0.94, recall = 0.91, mAP50 = 0.95, and mAP50-95 = 0.88. Findings indicate that the proposed system is feasible for real-time overloading monitoring, though performance remains sensitive to occlusion, lighting, crowd density, and network stability.
Zitieren
APA
Hellie, D. K., Barba, J. A., Calida, A. P., Diche, L., & Torre, J. D. (2026). Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm. Asian Research Journal of Information Technology, 3(3), 27-38. https://doi.org/10.66206/eduheart.arjit.3
Vancouver
Hellie DK, Barba JA, Calida AP, Diche L, Torre JD. Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm. Asian Research Journal of Information Technology. 2026;3(3):27-38. doi:10.66206/eduheart.arjit.3
BibTeX
@article{Hellie2026,
author = {Hellie, Dhane Kian and Barba, John Arnie and Calida, Ann Paulina and Diche, Lemuel and Torre, Jacqueline Dela},
title = {Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm},
journal = {Asian Research Journal of Information Technology},
year = {2026},
volume = {3},
number = {3},
pages = {27--38},
doi = {10.66206/eduheart.arjit.3}
}
EUVIMED