EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm

Dhane Kian Hellie, John Arnie Barba, Ann Paulina Calida, Lemuel Diche, Jacqueline Dela Torre

Asian Research Journal of Information Technology · 2026 · 3 (3) · 27-38

DOI: 10.66206/eduheart.arjit.3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Research Journal of Information Technology, 2026. Verfasst von Dhane Kian Hellie und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Overloading in public utility buses remains a persistent transportation safety and regulatory problem, particularly in urban environments, where monitoring is often conducted through manual inspection. This study developed and evaluated a non-contact overloading detection system for public utility buses using the YOLOv8 object detection algorithm, Raspberry Pi 4, camera module, GPS, and real-time alert transmission. The study employed a descriptive-developmental quantitative design and Agile software development methodology. Fifty respondents participated in the evaluation, consisting of 44 passengers and 6 authorities. System performance was assessed through controlled trials, ISO/IEC 25010-based survey questionnaires, and object detection metrics, including precision, recall, and mean average precision (mAP). Test trials showed detection accuracies ranging from 67% to 82%, with one case of over-detection. Real-time processing achieved an average speed of 0.04 to 0.09 seconds per frame. Survey-based evaluation indicated high acceptance across hardware detection (overall mean = 4.40), alert system performance (overall mean = 4.41), and real-world system performance (overall mean = 4.37). ISO/IEC 25010 evaluation also showed strong results in usability (4.46), security (4.44), maintainability (4.44), reliability (4.37), efficiency (4.37), and functionality (4.19). YOLOv8 performance metrics reported precision = 0.94, recall = 0.91, mAP50 = 0.95, and mAP50-95 = 0.88. Findings indicate that the proposed system is feasible for real-time overloading monitoring, though performance remains sensitive to occlusion, lighting, crowd density, and network stability.

Zitieren

APA

Hellie, D. K., Barba, J. A., Calida, A. P., Diche, L., & Torre, J. D. (2026). Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm. Asian Research Journal of Information Technology, 3(3), 27-38. https://doi.org/10.66206/eduheart.arjit.3

Vancouver

Hellie DK, Barba JA, Calida AP, Diche L, Torre JD. Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm. Asian Research Journal of Information Technology. 2026;3(3):27-38. doi:10.66206/eduheart.arjit.3

BibTeX
@article{Hellie2026,
  author = {Hellie, Dhane Kian and Barba, John Arnie and Calida, Ann Paulina and Diche, Lemuel and Torre, Jacqueline Dela},
  title = {Non-Contact Overloading Detection System for Public Utility Buses Using Yolov8 Algorithm},
  journal = {Asian Research Journal of Information Technology},
  year = {2026},
  volume = {3},
  number = {3},
  pages = {27--38},
  doi = {10.66206/eduheart.arjit.3}
}
Kostenlos starten →