The Effect of Intermediate Layer Materials on the Bond Strength to Hydraulic Calcium-Silicate–Based Cements Used in Vital Pulp Therapy: An In Vitro Study
European Endodontic Journal · 31.05.2026 · 11 (5) · 214-221
DOI: 10.65717/eej.2026.25178 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Endodontic Journal, online erschienen am 31.05.2026. Verfasst von João Filipe Brochado Martins und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, Netherlands. Hauptthemen laut MEDLINE: Silicates, Calcium Compounds, Dental Cements, Dental Bonding. Gefördert von: Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Netherlands.
Abstract (Originalsprache)
Objective
This in vitro study evaluated the shear bond strength (SBS) between 4 hydraulic calcium silicate–based cements (HCSCs) and 3 intermediate layer materials used in vital pulp therapy (VPT).
Methods
Two hundred forty specimens were divided into 12 groups and prepared using combinations of HCSCs (mineral trioxide aggregate [MTA], Biodentine, NeoPutty, MTA vital pulp therapy [MTAvpt]) and 3 intermediate layer materials (self-adhesive flowable composite [SAFC], resin-modified glass ionomer [RMGI], and flowable composite [FC]). SBS was measured using a universal testing machine, and failure modes were evaluated under stereomicroscopy. Data were analyzed using two-way ANOVA and Tukey’s test with an α=0.05.
Results
SBS was affected by HCSC (P < .001), intermediate layer material (P < .001), and their interaction (P=.016). Biodentine exhibited the highest mean SBS (17.24 ± 12.09 MPa), followed by MTAvpt (12.59 ± 10.22 MPa), MTA (11.04 ± 9.80 MPa), and NeoPutty (9.84 ± 10.60 MPa). For intermediate layer materials, SAFC demonstrated the highest mean SBS (21.17 ± 10.88 MPa), significantly greater than FC (13.41 ± 9.07 MPa), and RMGI (3.45 ± 2.52 MPa). The combination Biodentine-SAFC yielded the highest mean SBS value, while groups with RMGI showed the lowest SBS values, with predominantly adhesive failures.
Conclusion
Under the conditions of this in vitro study, bond strength between HCSCs and intermediate materials varied according to both material types. SAFC and, in some cases, FC exhibited higher initial adhesion to the tested HCSCs, while RMGI showed consistently low SBS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Endodontology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, Netherlands.
- Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, Netherlands.
- Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Department of Dental Materials Science, Amsterdam, The Netherlands.
ORCID-Profile: João Filipe Brochado Martins, Amanda Maria de Oliveira Dal Piva
Förderung
- Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Netherlands
Zitieren
APA
Brochado Martins, J. F., Kordestani, S., & Dal Piva, A. M. O. (2026). The Effect of Intermediate Layer Materials on the Bond Strength to Hydraulic Calcium-Silicate–Based Cements Used in Vital Pulp Therapy: An In Vitro Study. European Endodontic Journal, 11(5), 214-221. https://doi.org/10.65717/eej.2026.25178
Vancouver
Brochado Martins JF, Kordestani S, Dal Piva AMO. The Effect of Intermediate Layer Materials on the Bond Strength to Hydraulic Calcium-Silicate–Based Cements Used in Vital Pulp Therapy: An In Vitro Study. European Endodontic Journal. 2026;11(5):214-221. doi:10.65717/eej.2026.25178
BibTeX
@article{BrochadoMartins2026,
author = {Brochado Martins, João Filipe and Kordestani, Shayan and Dal Piva, Amanda Maria de Oliveira},
title = {The Effect of Intermediate Layer Materials on the Bond Strength to Hydraulic Calcium-Silicate–Based Cements Used in Vital Pulp Therapy: An In Vitro Study},
journal = {European Endodontic Journal},
year = {2026},
volume = {11},
number = {5},
pages = {214--221},
doi = {10.65717/eej.2026.25178}
}
EUVIMED