Accuracy of Digital Radiography and Cone Beam Computed Tomography in Assessing Filling Material Extrusion Using Micro- Computed Tomography as Gold Standard: A Study in Human Cadavers
European Endodontic Journal · 27.02.2026 · 11 (2) · 45-49
DOI: 10.65717/eej.2026.25090 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Endodontic Journal, online erschienen am 27.02.2026. Verfasst von Thamyres Monteiro und 6 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Radiography, Dental, Digital, Root Canal Filling Materials, X-Ray Microtomography.
Abstract (Originalsprache)
Objective
This study compared the accuracy of digital periapical radiography (DPR) and cone beam computed tomography (CBCT) in detecting extruded filling material, using a human cadaver model. Microcomputed tomography (Micro-CT) served as the gold standard.
Methods
A total of 27 single-rooted teeth embedded in cadaveric mandibular segments, obtained from a prior retreatment study, were included: 25 with confirmed apical extrusion of filling material on micro-CT and 2 without extrusion serving as negative controls. The segments were imaged using both DPR and CBCT. Two calibrated endodontists independently assessed the images for visible extrusion; discrepancies were resolved by a third evaluator.
Results
Although DPR demonstrated lower overall sensitivity than CBCT, both modalities showed identical specificity (100%). Diagnostic accuracy was 70% for DPR and 74% for CBCT, without statistically significant difference between them (P > .05). Moreover, the volume of extruded filling material was not a significant predictor of detection accuracy for either DPR (P > .05) or CBCT (P > .05).
Conclusion
In conclusion, both DPR and CBCT demonstrated low accuracy in detecting filling material extrusion, with no significant difference between them. The occurrence of false-negative results may compromise the reliable assessment of extruded filling materials. In cases of true extrusion, approximately one-third would go undetected by both methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, RJ, Brazil.
- Department of Restorative Dentistry, UNIFACOL University Center, Vitória de Santo Antão, PE, Brazil.
- Laboratory of Molecular Microbial Ecology, Paulo de Góes Institute of Microbiology, Center for Health Sciences, FederalUniversity of Rio de Janeiro (UFRJ), RJ, Brazil.
- Postgraduate Program in Dentistry, Faculty of Dentistry, Iguaçu University (UNIG), Nova Iguaçu, RJ, Brazil.
- Department of Endodontics, Maurício de Nassau University Centre (UNINASSAU), Rio de Janeiro, Brazil.
- Department of Dental Research Cell, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. PatilVidyapeeth, Pune 411018, India.
ORCID-Profile: Thamyres Monteiro, Kaline Romeiro, Karen Brisson-Suárez, Karim Aazzouzi-Raiss, Marília Marceliano-Alves, Andrea Campello, Flávio Alves
Zitieren
APA
Monteiro, T., Romeiro, K., Brisson-Suárez, K., Aazzouzi-Raiss, K., Marceliano-Alves, M., Campello, A., & Alves, F. (2026). Accuracy of Digital Radiography and Cone Beam Computed Tomography in Assessing Filling Material Extrusion Using Micro- Computed Tomography as Gold Standard: A Study in Human Cadavers. European Endodontic Journal, 11(2), 45-49. https://doi.org/10.65717/eej.2026.25090
Vancouver
Monteiro T, Romeiro K, Brisson-Suárez K, Aazzouzi-Raiss K, Marceliano-Alves M, Campello A, et al. Accuracy of Digital Radiography and Cone Beam Computed Tomography in Assessing Filling Material Extrusion Using Micro- Computed Tomography as Gold Standard: A Study in Human Cadavers. European Endodontic Journal. 2026;11(2):45-49. doi:10.65717/eej.2026.25090
BibTeX
@article{Monteiro2026,
author = {Monteiro, Thamyres and Romeiro, Kaline and Brisson-Suárez, Karen and Aazzouzi-Raiss, Karim and Marceliano-Alves, Marília and Campello, Andrea and Alves, Flávio},
title = {Accuracy of Digital Radiography and Cone Beam Computed Tomography in Assessing Filling Material Extrusion Using Micro- Computed Tomography as Gold Standard: A Study in Human Cadavers},
journal = {European Endodontic Journal},
year = {2026},
volume = {11},
number = {2},
pages = {45--49},
doi = {10.65717/eej.2026.25090}
}
EUVIMED