Seasonally Shaded Trombe Wall for Improved Annual Thermal Comfort and Energy Performance in a Hot Summer - Cold Winter Climate

Meixin Wu, Francisco Mateo-Elgueda, Yuehong Su

Research and Reviews in Sustainability · 20.04.2026 · 2 · 162-178

DOI: 10.65582/rrs.2026.010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Research and Reviews in Sustainability, online erschienen am 20.04.2026. Verfasst von Meixin Wu und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agencia Nacional de Investigación y Desarrollo.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Addressing the critical challenge of summer overheating in passive solar systems, this study evaluates the year-round thermal and energy performance of a seasonally shaded and fan-assisted Trombe wall in Beijing’s Hot-Summer - Cold-Winter (HSCW) climate. Using a simulation-based approach, four facade configurations were compared against a standard south-facing window baseline. Results demonstrate that while an unshaded Trombe wall (TW) reduces annual heating demand by 27%, it imposes a 25% cooling penalty. The permanent deployment of external blinds (TW+Blinds) from May to September effectively mitigates this impact, reducing the cooling load by 13% compared to the unshaded configuration and limiting the final summer penalty to only 8.7% above the baseline. The hybrid configuration, incorporating both seasonal shading and an auxiliary cavity fan (TW+Blinds+Fan), achieves the highest overall performance, delivering a 30.3% reduction in annual heating demand and a 14% net saving in total annual energy use. Furthermore, annual thermal habitability improves by 20.7% based on the frequency of occupied hours maintained within the 20 °C to 26 °C safety range. The analysis identifies seasonal shading as the primary driver for annual balance, while the performance decrease observed in April reveals that fixed-schedule fan assistance introduces operational trade-offs during transitional months.

Förderung

  • Agencia Nacional de Investigación y Desarrollo

Zitieren

APA

Wu, M., Mateo-Elgueda, F., & Su, Y. (2026). Seasonally Shaded Trombe Wall for Improved Annual Thermal Comfort and Energy Performance in a Hot Summer - Cold Winter Climate. Research and Reviews in Sustainability, 2, 162-178. https://doi.org/10.65582/rrs.2026.010

Vancouver

Wu M, Mateo-Elgueda F, Su Y. Seasonally Shaded Trombe Wall for Improved Annual Thermal Comfort and Energy Performance in a Hot Summer - Cold Winter Climate. Research and Reviews in Sustainability. 2026;2:162-178. doi:10.65582/rrs.2026.010

BibTeX
@article{Wu2026,
  author = {Wu, Meixin and Mateo-Elgueda, Francisco and Su, Yuehong},
  title = {Seasonally Shaded Trombe Wall for Improved Annual Thermal Comfort and Energy Performance in a Hot Summer - Cold Winter Climate},
  journal = {Research and Reviews in Sustainability},
  year = {2026},
  volume = {2},
  pages = {162--178},
  doi = {10.65582/rrs.2026.010}
}
Kostenlos starten →