Design-operation-performance coupling in contemporary HVAC systems: A system-level review

Yusuf Nadir Yilmaz, Emre Alvur, Pinar Mert Cuce, Erdem Cuce

Green Technology & Innovation · 01.06.2026 · 2 · 267-293

DOI: 10.65582/gti.2026.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Green Technology & Innovation, online erschienen am 01.06.2026. Verfasst von Yusuf Nadir Yilmaz und 3 weiteren Autor:innen. Die Arbeit nennt 141 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heating, ventilation, and air-conditioning (HVAC) systems play a decisive role in the energy consumption, indoor environmental quality, and carbon footprint of contemporary buildings. Despite significant advances in high-efficiency equipment and control technologies, a persistent gap remains between nominal efficiency ratings and realised in-use performance. This discrepancy is primarily driven by dynamic operating conditions, part-load behaviour, climatic variability, and cross-layer misalignment between system design, operational control, and environmental demands. This review adopts a system-level perspective to examine how HVAC performance is shaped through the coupling of design configuration, equipment modulation capability, supervisory control architecture, and sensible-latent load interaction. Rather than treating system typologies, control strategies, and performance metrics as isolated domains, the study organises existing literature within a structured design-operation-performance coupling framework. Centralised, decentralised, and hybrid HVAC configurations are critically reviewed with particular emphasis on part-load thermodynamics, ventilation-humidity interaction, and control coordination under real building conditions. The analysis reveals that nominal efficiency indicators such as the coefficient of performance (COP) and seasonal ratings represent equipment potential rather than guaranteed operational outcomes. Performance degradation commonly emerges from conservative sizing practices, limited turndown capability, inadequate supervisory coordination, and humidity-dominated operating regimes, especially in ventilated and humid climates. The review further highlights that effective performance realisation depends less on individual component efficiency and more on the coherence between system architecture, modulation strategy, and control hierarchy. By synthesising experimental findings, field studies, and simulation-based research, this work provides an integrated evaluation logic for interpreting HVAC efficiency beyond static ratings. The proposed framework supports more reliable performance assessment, informs design and commissioning practices, and contributes to narrowing the persistent gap between predicted and realised HVAC performance in contemporary low-carbon buildings.

Zitieren

APA

Yilmaz, Y. N., Alvur, E., Cuce, P. M., & Cuce, E. (2026). Design-operation-performance coupling in contemporary HVAC systems: A system-level review. Green Technology & Innovation, 2, 267-293. https://doi.org/10.65582/gti.2026.013

Vancouver

Yilmaz YN, Alvur E, Cuce PM, Cuce E. Design-operation-performance coupling in contemporary HVAC systems: A system-level review. Green Technology & Innovation. 2026;2:267-293. doi:10.65582/gti.2026.013

BibTeX
@article{Yilmaz2026,
  author = {Yilmaz, Yusuf Nadir and Alvur, Emre and Cuce, Pinar Mert and Cuce, Erdem},
  title = {Design-operation-performance coupling in contemporary HVAC systems: A system-level review},
  journal = {Green Technology & Innovation},
  year = {2026},
  volume = {2},
  pages = {267--293},
  doi = {10.65582/gti.2026.013}
}
Kostenlos starten →