Instability-Aware Digital Twin Control for Grid-Constrained Low-Carbon Smart Ports
Energy Catalyst · 07.10.2026 · 2 · 132-168
DOI: 10.65582/ec.2026.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energy Catalyst, online erschienen am 07.10.2026. Verfasst von Seyed Reza Samaei und 2 weiteren Autor:innen. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Modern smart ports combine terminal electrification, shore power, renewable generation, storage, and digital operational control under uncertain vessel traffic and time-varying grid limits. This study develops a simulation-based digital-twin control prototype that synchronizes vessel flow, berth occupancy, equipment activity, shore-power demand, renewable supply, battery state, grid import, and modelled emissions. A policy-weighted Instability Propagation Index (IPI) classifies lower-stress, critical-transition, and instability-dominated operating regimes and is embedded in an NSGA-II rolling-horizon controller for berth allocation, crane scheduling, vessel sequencing, shore-power timing, flexible loads, renewable curtailment, and battery dispatch. The confirmatory analysis uses a 720-h coupled congestion-and-grid-limit benchmark with 30 paired common-random-number replications, service-preservation controls, terminal-horizon accounting, optimizer-seed verification, and distribution-robust statistics. Relative to operation-focused, energy-focused, and decoupled policies, the proposed controller reduces operational energy by 8.9–21.2%, modelled grid-plus-queue emissions by 8.5–21.0%, peak grid import by 5.7–15.1%, and mean replication-level maximum IPI by 24.8–42.3%, while achieving the lowest composite vessel delay and highest berth-utilization efficiency. A 23 MW renewable portfolio with an 8 MW/16 MWh battery reduces net grid import from 14,510 to 8,370 MWh, peak import from 54.9 to 46.2 MW, modelled emissions from 8,040 to 4,847 tCO₂e, and mean maximum IPI from 0.82 to 0.68. The results demonstrate coordinated logistics–energy control within an externally grounded synthetic benchmark whose principal digital-twin, equipment, and shore-power operating scales are supported by published real-terminal evidence. Deployment at a specific port would nevertheless require local calibration of arrival, service, grid, emission, and control parameters.
Zitieren
APA
Samaei, S. R., Reddy, K. S., & Riffat, J. (2026). Instability-Aware Digital Twin Control for Grid-Constrained Low-Carbon Smart Ports. Energy Catalyst, 2, 132-168. https://doi.org/10.65582/ec.2026.007
Vancouver
Samaei SR, Reddy KS, Riffat J. Instability-Aware Digital Twin Control for Grid-Constrained Low-Carbon Smart Ports. Energy Catalyst. 2026;2:132-168. doi:10.65582/ec.2026.007
BibTeX
@article{Samaei2026,
author = {Samaei, Seyed Reza and Reddy, K. S. and Riffat, James},
title = {Instability-Aware Digital Twin Control for Grid-Constrained Low-Carbon Smart Ports},
journal = {Energy Catalyst},
year = {2026},
volume = {2},
pages = {132--168},
doi = {10.65582/ec.2026.007}
}
EUVIMED