EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AI-Based Occupancy Detection for HVAC-Relevant Load Estimation in a University Building

Rufus Dwamena, Wuxia Zhang, Paige Tien, John Calautit, Hao Sun

Artificial Intelligence for Sustainable Cities · 30.06.2026 · 1 · 187-201

DOI: 10.65582/aifsc.2026.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Intelligence for Sustainable Cities, online erschienen am 30.06.2026. Verfasst von Rufus Dwamena und 4 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Occupancy-aware HVAC control depends on realistic estimates of occupant-related heat gains, yet many buildings still operate on static schedules that assume sustained high occupancy. This study evaluated whether a vision-based people detector could generate a more representative occupancy schedule for a university seminar room. Two YOLOv7 models were trained on 500 annotated images, including five null images, and deployed to two simultaneous 60-minute recordings of room B5 in the Marmont Centre, University of Nottingham, from front-right and back-left viewpoints. Held-out validation favoured the extended Google Colab configuration over the Roboflow configuration, with mAP, precision and recall of 88.4%, 89.3% and 85.8% versus 86.9%, 84.1% and 80.9%, respectively. Against minute-by-minute manual counts, the best configuration - Google Colab with the front-right view - achieved a normalized count accuracy of 95.8%. Occupancy counts were translated into occupant heat-gain schedules using CIBSE benchmark data. The best dynamic schedule yielded a reconstructed mean occupant gain of 2.37 kW compared with 4.48 kW for a static seminar-room benchmark. Within the original EnergyPlus comparison framework, the best dynamic schedule corresponded to normalized winter-heating and summer-cooling indices of 73.3 and 32.4 relative to a static benchmark of 100, equivalent to reductions of 26.7% and 67.6%. The results show that camera placement and occlusion are as important as model choice and that vision-based occupancy detection can materially improve HVAC-relevant schedule realism in teaching spaces, provided that both counting accuracy and the direction of counting error are validated.

Zitieren

APA

Dwamena, R., Zhang, W., Tien, P., Calautit, J., & Sun, H. (2026). AI-Based Occupancy Detection for HVAC-Relevant Load Estimation in a University Building. Artificial Intelligence for Sustainable Cities, 1, 187-201. https://doi.org/10.65582/aifsc.2026.011

Vancouver

Dwamena R, Zhang W, Tien P, Calautit J, Sun H. AI-Based Occupancy Detection for HVAC-Relevant Load Estimation in a University Building. Artificial Intelligence for Sustainable Cities. 2026;1:187-201. doi:10.65582/aifsc.2026.011

BibTeX
@article{Dwamena2026,
  author = {Dwamena, Rufus and Zhang, Wuxia and Tien, Paige and Calautit, John and Sun, Hao},
  title = {AI-Based Occupancy Detection for HVAC-Relevant Load Estimation in a University Building},
  journal = {Artificial Intelligence for Sustainable Cities},
  year = {2026},
  volume = {1},
  pages = {187--201},
  doi = {10.65582/aifsc.2026.011}
}