Fachartikel in der Zeitschrift Artificial Intelligence for Sustainable Cities, online erschienen am 17.03.2026. Verfasst von Seyed Reza Samaei und 1 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Climate change is increasingly exposing building energy systems to prolonged and severe thermal stress, revealing fundamental limitations in conventional control strategies that rely on static models and reactive feedback. Under extreme heatwave conditions, buildings often experience gradual performance drift driven by equipment degradation, sensing bias, and evolving internal loads, leading to declining energy efficiency and growing thermal discomfort. Existing control architectures, however, lack the capability to interpret the underlying causes of these deviations or to adapt their operation in a timely and causally informed manner. This study proposes a cognitive digital twin framework that shifts building energy management from reactive regulation toward diagnosis-informed and adaptive control under climate-extreme operation. The framework integrates physics-based building energy modeling with real-time sensing and data assimilation to enable continuous state estimation, early detection of performance drift, and explicit root-cause attribution. Diagnostic information is embedded in the control loop, enabling actions based on diagnosed system states rather than predictive trajectories or residual feedback. Cognition emerges from the interaction of interpretation, reasoning, and memory as conditions evolve. The framework is tested on a medium-scale office building with a variable air volume HVAC system under heatwave-driven stress scenarios, including cooling degradation, sensor drift, demand response limits, occupancy shocks, and uncertainty across hot-dry, hot-humid, and temperate climates. Compared with rule-based control, conventional model predictive control, and a non-cognitive digital twin, the approach reduces energy use intensity by 10.9%, peak demand by 13.4%, and discomfort hours by 54.6%. It detects performance drift 3.3–3.4× earlier, cuts unmet cooling hours by 58.2%, and speeds post-event comfort recovery by ~46%. These results show that cognitive digital twins can act as self-interpreting, adaptive building energy systems, supporting resilient energy performance and thermal comfort under climate extremes.
Zitieren
APA
Samaei, S. R., & Riffat, J. (2026). Cognitive Digital Twins for Climate-Resilient Building Energy Systems: Diagnosis-Informed Control under Extreme Thermal Stress. Artificial Intelligence for Sustainable Cities, 1, 71-104. https://doi.org/10.65582/aifsc.2026.005
Vancouver
Samaei SR, Riffat J. Cognitive Digital Twins for Climate-Resilient Building Energy Systems: Diagnosis-Informed Control under Extreme Thermal Stress. Artificial Intelligence for Sustainable Cities. 2026;1:71-104. doi:10.65582/aifsc.2026.005
BibTeX
@article{Samaei2026,
author = {Samaei, Seyed Reza and Riffat, James},
title = {Cognitive Digital Twins for Climate-Resilient Building Energy Systems: Diagnosis-Informed Control under Extreme Thermal Stress},
journal = {Artificial Intelligence for Sustainable Cities},
year = {2026},
volume = {1},
pages = {71--104},
doi = {10.65582/aifsc.2026.005}
}
EUVIMED