EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

EffRes-Bio: Lightweight Cross-Sensor Fingerprint Verification with a Controlled Evaluation of Frequency-Aware Attention

Khalid Jajan, Wafaa Mustafa Abduallah

Dasinya Journal for Engineering and Informatics · 13.11.2026 · 2 (4)

DOI: 10.65542/djei.v2i4.104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dasinya Journal for Engineering and Informatics, online erschienen am 13.11.2026. Verfasst von Khalid Jajan und 1 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fingerprint verification on resource-constrained devices requires compact models that generalise across heterogeneous capture sensors. This paper presents EffRes-Bio, a fingerprint feature extractor of 4.34 million parameters and 0.39 GMACs that combines an ImageNet-pretrained EfficientNet-B0 backbone with generalised-mean pooling and an ArcFace embedding head, and uses it to test whether a frequency-aware channel attention (FAA) module improves transfer to unseen sensors. Models are evaluated on the three real-sensor FVC2002 databases under an open-set protocol; cross-sensor results use a leave-one-sensor-out design repeated over three random seeds, giving nine paired observations per model. Because the databases differ in fingers as well as sensors, this protocol measures generalisation to unseen sensors rather than strict interoperability. On unseen sensors, EffRes-Bio attains a mean equal error rate (EER) of 19.55 %, statistically indistinguishable from ResNet-50 (18.70 %, p = 0.39), which has 5.5 times more parameters and 10.3 times more computation, while running 3.4 times faster on a single CPU thread. It outperforms MobileNetV3-Small (22.47 %) by 2.91 percentage points (95 % CI 1.15–4.67, p = 0.005), a difference that survives Holm correction. Within a database, the three networks do not differ significantly. FAA did not improve cross-sensor performance in any of the three tested forms, and a sampling analysis explains the null result at the final feature map, where the ridge period falls to 0.13–0.21 pixels. Finally, deriving a baseline's first layer from its pretrained weights rather than re-initialising it lowered its cross-sensor EER by 2.8–3.5 points, more than any architectural difference observed.

Zitieren

APA

Jajan, K., & Abduallah, W. M. (2026). EffRes-Bio: Lightweight Cross-Sensor Fingerprint Verification with a Controlled Evaluation of Frequency-Aware Attention. Dasinya Journal for Engineering and Informatics, 2(4). https://doi.org/10.65542/djei.v2i4.104

Vancouver

Jajan K, Abduallah WM. EffRes-Bio: Lightweight Cross-Sensor Fingerprint Verification with a Controlled Evaluation of Frequency-Aware Attention. Dasinya Journal for Engineering and Informatics. 2026;2(4). doi:10.65542/djei.v2i4.104

BibTeX
@article{Jajan2026,
  author = {Jajan, Khalid and Abduallah, Wafaa Mustafa},
  title = {EffRes-Bio: Lightweight Cross-Sensor Fingerprint Verification with a Controlled Evaluation of Frequency-Aware Attention},
  journal = {Dasinya Journal for Engineering and Informatics},
  year = {2026},
  volume = {2},
  number = {4},
  doi = {10.65542/djei.v2i4.104}
}
Kostenlos starten →