EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Comparison of Hemoglobin Levels by Copper Sulphate Method and Automated Hematology Analyzer in Blood Donors

Muhammad Ansar, Muhammad Saeed, Kanwal Shehzadi, Hira Ali, Muhammad Saifur Rehman

Mirpur Journal of Medical Sciences · 2024

DOI: 10.65433/mjms.v1i2.18 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mirpur Journal of Medical Sciences, 2024. Verfasst von Muhammad Ansar und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To contrast the Hb results obtained using CuSO4 method and automated analyzer and to investigate how donor deferral is affected by the CuSO4 method's inaccuracy. Methodology: The study was conducted in Blood bank of Holy Family Hospital, Benazir Bhutto Hospital, District Headquarters Hospital and Hematology Laboratory, Pathology Department of Holy Family Hospital, Rawalpindi. Capillary and venous blood sample were tested by using Hb screening appropriate standardized CuSO4 test (1.053) alongside the automated hematology analyzer, which was regarded as the industry standard reference technique.

Results

Results of copper sulphate were interpreted as Pass or Fail at Hb cut off of ≥12.5 g/dl. By this method, a total of 20 (16.6%) blood donors were deferred, out of which 15 were male and 5 were female. The percentage of deferrals was greater in women. (62.5%) in contrast to men. (13.3%) By Automated Hematology Analyzer (Sysmex-KX21) method, only 15 blood donors were deferred, out of which 11(10%) were male and 4 (50%) were female. The sensitivity of the CuSO4 was (95.24%), specificity (100%), PPV (100%), NPV (75%) and the sensitivity of automated hematology analyzer was (100%), specificity (100%), PPV (100%), NPV (100%).

Conclusion

The accuracy of CuSO4 was (95.83%) and the accuracy of the automated hematology analyzer is (100%). The inaccuracy of CuSO4 was 4.17%.

Zitieren

APA

Ansar, M., Saeed, M., Shehzadi, K., Ali, H., & Rehman, M. S. (2024). Comparison of Hemoglobin Levels by Copper Sulphate Method and Automated Hematology Analyzer in Blood Donors. Mirpur Journal of Medical Sciences. https://doi.org/10.65433/mjms.v1i2.18

Vancouver

Ansar M, Saeed M, Shehzadi K, Ali H, Rehman MS. Comparison of Hemoglobin Levels by Copper Sulphate Method and Automated Hematology Analyzer in Blood Donors. Mirpur Journal of Medical Sciences. 2024. doi:10.65433/mjms.v1i2.18

BibTeX
@article{Ansar2024,
  author = {Ansar, Muhammad and Saeed, Muhammad and Shehzadi, Kanwal and Ali, Hira and Rehman, Muhammad Saifur},
  title = {Comparison of Hemoglobin Levels by Copper Sulphate Method and Automated Hematology Analyzer in Blood Donors},
  journal = {Mirpur Journal of Medical Sciences},
  year = {2024},
  doi = {10.65433/mjms.v1i2.18}
}
Kostenlos starten →