Detection of Chronic Load Imbalance and Hot-Spot Risk in Building Electrical Systems using Long-Term Three-Phase Current Analysis and Mechanism-Informed Artificial Intelligence
Recent Science and Technology · 29.09.2026 · 18 (3) · e271202
DOI: 10.65411/rst.2026.271202 ↗Kurz gefasst
Fachartikel in der Zeitschrift Recent Science and Technology, online erschienen am 29.09.2026. Verfasst von Sittisak Rojchaya und 1 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Infrared thermography detects hot spots only at the time of inspection, whereas electrical system degradation evolves continuously through the 24/7 accumulation of operational stress. This study proposes a novel mechanism-informed predictive monitoring framework that integrates long-term three-phase current data with a physics-guided machine-learning inference model to identify early degradation signatures before infrared-detectable heating occurs. Results synthesized from multiple degradation indicators reveal that Phase B exhibits persistent structural dominance, with a mean occupancy of 56% (peaking at 71%), and accumulates 2.35 times the thermal debt of Phase A. This imbalance produces pronounced thermal memory, whereby 38% of thermal stress remains unrecovered after load reduction, resulting in the fastest insulation aging (aging rate = 0.0028; final Aging Index = 0.95). Notably, the proposed system degradation collapse index exceeds the critical degradation threshold (0.70) despite the absence of overload or fault conditions under conventional protection criteria. The proposed framework provides a continuous, low-cost, and practical solution for 24/7 predictive condition monitoring, enabling electrical hazards to be identified before hot spots and failures occur while overcoming the limitations of snapshot-based inspections.
Zitieren
APA
Rojchaya, S., & karisan, S. (2026). Detection of Chronic Load Imbalance and Hot-Spot Risk in Building Electrical Systems using Long-Term Three-Phase Current Analysis and Mechanism-Informed Artificial Intelligence. Recent Science and Technology, 18(3), e271202. https://doi.org/10.65411/rst.2026.271202
Vancouver
Rojchaya S, karisan S. Detection of Chronic Load Imbalance and Hot-Spot Risk in Building Electrical Systems using Long-Term Three-Phase Current Analysis and Mechanism-Informed Artificial Intelligence. Recent Science and Technology. 2026;18(3):e271202. doi:10.65411/rst.2026.271202
BibTeX
@article{Rojchaya2026,
author = {Rojchaya, Sittisak and karisan, Santi},
title = {Detection of Chronic Load Imbalance and Hot-Spot Risk in Building Electrical Systems using Long-Term Three-Phase Current Analysis and Mechanism-Informed Artificial Intelligence},
journal = {Recent Science and Technology},
year = {2026},
volume = {18},
number = {3},
pages = {e271202},
doi = {10.65411/rst.2026.271202}
}
EUVIMED