East-West Coordination and Economic Dispatch of Libya's Power System: Economic Value and Transmission Capacity Sensitivity
Al-Farooq Journal of Sciences · 20.11.2026 · 2 (4) · 1577-1593
DOI: 10.65405/djjst098 ↗Kurz gefasst
Fachartikel in der Zeitschrift Al-Farooq Journal of Sciences, online erschienen am 20.11.2026. Verfasst von Osama Mohammed Abdulrahman und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Independent day-ahead scheduling in interconnected regions can meet the needs of each region, the system-level economic efficiency is low due to the failure to fully utilize the limited exchanges between regions in the scheduling sequence. This paper constructs a 24-hour mixed-integer linear programming model for the Libyan power system to coordinate and optimize unit combination, start-up and shutdown decisions, economic dispatch, and the total east-west exchange variable. Controlled experiments were conducted under three frameworks with the same regional demand, initial state, unit constraints, time constraints, and calibrated cost coefficients: independent scheduling with zero exchange, coordinated scheduling with an exchange limit of 349.6 MW, and a virtually unconstrained mixed baseline. The study is evaluated based on data from 19 authorized operating days starting in 2025, consisting of 25 thermal power plant modules. The MATLAB optimization toolbox provides the main solution, while independent SciPy/ HiGHS reconstructions validate the objective function, completeness, regional balance, ramp-up capability, and minimum time residual. Throughout the sample, coordinated operation reduced the total target capacity from 97.759 million comparative cost units (CUs) to 97.094 million, achieving 86.17% of the combined economic value, reducing the average committed operating units from 9.80 to 9.11, and decreasing the total number of start-ups and shutdowns from 205 to 196. The coordinated operation plan transmitted 105.85 GWh of absolute power and 87.32 GWh of net power from east to west, with model-predicted load shedding at zero. On peak-value days, the target capacity decreased by 1.448%; on peak days of 8166 MW, the decrease was 0.157%. Transmission capacity sensitivity analysis revealed diminishing returns: high-value cases reached saturation near 750 MW, while peak cases achieved almost all available benefits at 500 MW. These results provide a quantitative screening method for prioritizing detailed national grid studies and developing coordinated operation policies.
Zitieren
APA
Abdulrahman, O. M., Al-Farah, R., Al-Gnoni, A., & Hussian, A. A. M. (2026). East-West Coordination and Economic Dispatch of Libya's Power System: Economic Value and Transmission Capacity Sensitivity. Al-Farooq Journal of Sciences, 2(4), 1577-1593. https://doi.org/10.65405/djjst098
Vancouver
Abdulrahman OM, Al-Farah R, Al-Gnoni A, Hussian AAM. East-West Coordination and Economic Dispatch of Libya's Power System: Economic Value and Transmission Capacity Sensitivity. Al-Farooq Journal of Sciences. 2026;2(4):1577-1593. doi:10.65405/djjst098
BibTeX
@article{Abdulrahman2026,
author = {Abdulrahman, Osama Mohammed and Al-Farah, Reyad and Al-Gnoni, Almonir and Hussian, Abdelgani A Mostafa},
title = {East-West Coordination and Economic Dispatch of Libya's Power System: Economic Value and Transmission Capacity Sensitivity},
journal = {Al-Farooq Journal of Sciences},
year = {2026},
volume = {2},
number = {4},
pages = {1577--1593},
doi = {10.65405/djjst098}
}
EUVIMED