Evaluating the HVAC System Design for Operating Rooms in Nalut Central Hospital According to International Standards
Al-Farooq Journal of Sciences · 30.07.2026 · 2 (ملحق 3) · 1216-1224
DOI: 10.65405/1qv5xy83 ↗Kurz gefasst
Fachartikel in der Zeitschrift Al-Farooq Journal of Sciences, online erschienen am 30.07.2026. Verfasst von Ghaith Almahdi und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This research aims to evaluate the Heating, Ventilation, and Air Conditioning (HVAC) system in the operating theaters of Nalut Central Hospital and analyze its compliance with approved international standards such as ASHRAE Standard 170 and WHO Guidelines for Surgery. The study adopted a comprehensive analytical approach, combining field visits, technical records review, and direct interviews with staff to assess the system's performance and adherence to modern operating room requirements. The findings revealed that the previously used non-centralized HVAC system had significantly exceeded its recommended operational lifespan. It failed to achieve essential requirements, including positive pressure, standard Air Change Rates (ACH), or precise temperature/humidity control. Currently, the hospital relies on household air conditioners (Split Units) and natural ventilation, which are entirely incompatible with surgical requirements, posing a significant risk of Surgical Site Infections (SSI). The study concluded that the current system is unable to meet standard specifications, necessitating immediate corrective actions, including the installation of a compliant centralized HVAC system.
Zitieren
APA
Almahdi, G., Ramadan, R., Ayub, D., Askar, M., & Fawzi, M. (2026). Evaluating the HVAC System Design for Operating Rooms in Nalut Central Hospital According to International Standards. Al-Farooq Journal of Sciences, 2(ملحق 3), 1216-1224. https://doi.org/10.65405/1qv5xy83
Vancouver
Almahdi G, Ramadan R, Ayub D, Askar M, Fawzi M. Evaluating the HVAC System Design for Operating Rooms in Nalut Central Hospital According to International Standards. Al-Farooq Journal of Sciences. 2026;2(ملحق 3):1216-1224. doi:10.65405/1qv5xy83
BibTeX
@article{Almahdi2026,
author = {Almahdi, Ghaith and Ramadan, Rayan and Ayub, Doha and Askar, Manal and Fawzi, Mona},
title = {Evaluating the HVAC System Design for Operating Rooms in Nalut Central Hospital According to International Standards},
journal = {Al-Farooq Journal of Sciences},
year = {2026},
volume = {2},
number = {ملحق 3},
pages = {1216--1224},
doi = {10.65405/1qv5xy83}
}
EUVIMED