Laser Surface Treatment of Dental Implants: Impact on Osseointegration and Peri-Implantitis Management
Dentistry: Theory and Practice · 14.06.2026 · 4 (1) · 19
DOI: 10.65324/dtp007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry: Theory and Practice, online erschienen am 14.06.2026. Verfasst von Ekaterina Dyachkova und 2 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Background
Dental implantation is the gold standard for rehabilitation of patients with partial and complete tooth loss. The surface condition of implants is a key determinant of long-term survival — both at placement (in terms of roughness and biocompatibility) and at late stages when inflammatory complications arise. Laser technologies occupy a prominent place among methods of implant surface modification and decontamination.
Objective
To analyze data on the use of different laser types for primary dental implant surface treatment and decontamination in peri-implantitis, and to assess the pattern of micro-relief damage at various laser parameters. Materials and methods. An in vitro experimental study was conducted using scanning electron microscopy (SEM) of dental implant surfaces (Straumann, Astra Tech, Osstem, Alpha Bio) following exposure to a diode laser «LSP-IRE-Polyus» (970 nm) and a Nd:YAG laser at power settings of 1 W and 2 W. Surface damage was graded on a 0–5-point scale.
Results
The 970 nm diode laser at 1 W caused no damage to any of the studied implant surfaces (0 points), comparable to the pre-experimental intact surface. At 2 W, minor micro-relief disruptions (1–2 points) were detected only in Osstem and Alpha Bio implants. In contrast, the Nd:YAG laser at 1 W caused severe surface damage to all implants (2–5 points), including complete micro-relief disruption, delamination, and visible cracks. At 2 W, the damage was catastrophic.
Conclusion
The 970 nm diode laser at 1 W provides effective bactericidal action with minimal implant surface damage and can be recommended for clinical use in peri-implantitis treatment. The Nd:YAG laser at equivalent parameters is not recommended due to significant structural surface damage.
Zitieren
APA
Dyachkova, E., Kazumova, A., & Stroganova, V. (2026). Laser Surface Treatment of Dental Implants: Impact on Osseointegration and Peri-Implantitis Management. Dentistry: Theory and Practice, 4(1), 19. https://doi.org/10.65324/dtp007
Vancouver
Dyachkova E, Kazumova A, Stroganova V. Laser Surface Treatment of Dental Implants: Impact on Osseointegration and Peri-Implantitis Management. Dentistry: Theory and Practice. 2026;4(1):19. doi:10.65324/dtp007
BibTeX
@article{Dyachkova2026,
author = {Dyachkova, Ekaterina and Kazumova, Aglaya and Stroganova, Victoria},
title = {Laser Surface Treatment of Dental Implants: Impact on Osseointegration and Peri-Implantitis Management},
journal = {Dentistry: Theory and Practice},
year = {2026},
volume = {4},
number = {1},
pages = {19},
doi = {10.65324/dtp007}
}
EUVIMED