Case study on seismic assessment of rcc buildings with strengthened columns after floor addition
INDIAN CONCRETE JOURNAL · 2026 · 100 (10) · 26-40
DOI: 10.65302/icj.2026.100102 ↗Kurz gefasst
Fachartikel in der Zeitschrift INDIAN CONCRETE JOURNAL, 2026. Verfasst von NIHARIKA P und 1 weiteren Autor:innen.
Abstract (Originalsprache)
This study investigates the seismic performance of existing four, five and six storey reinforced cement concrete (RCC) buildings after the addition of an extra floor, which compromises their seismic safety. A nonlinear static pushover analysis was conducted using commercial finite element–based structural analysis software to evaluate structural response in Seismic Zones II–IV as per IS: 1893 (2016)[1]. The analysis revealed column failures at lower floors, which were subsequently strengthened with 100 mm concrete jackets. Following strengthening, the buildings were reassessed for seismic safety using equivalent static analysis (Level I) and nonlinear static pushover analysis (Level II). This study evaluates concrete jacketing as a strengthening technique for mid-rise RC frames situated in Indian Seismic Zones II–IV, addressing deficiencies in shear resistance and ductility across low to severe seismic hazard contexts.
Zitieren
APA
P, N., & KUMAR, P. R. P. (2026). Case study on seismic assessment of rcc buildings with strengthened columns after floor addition. INDIAN CONCRETE JOURNAL, 100(10), 26-40. https://doi.org/10.65302/icj.2026.100102
Vancouver
P N, KUMAR PRP. Case study on seismic assessment of rcc buildings with strengthened columns after floor addition. INDIAN CONCRETE JOURNAL. 2026;100(10):26-40. doi:10.65302/icj.2026.100102
BibTeX
@article{P2026,
author = {P, NIHARIKA and KUMAR, PROF. RAMANCHARLA PRADEEP},
title = {Case study on seismic assessment of rcc buildings with strengthened columns after floor addition},
journal = {INDIAN CONCRETE JOURNAL},
year = {2026},
volume = {100},
number = {10},
pages = {26--40},
doi = {10.65302/icj.2026.100102}
}
EUVIMED