Comparison of manual goniometry and kinovea-based photogrammetry for infrasternal angle assessment

Sonja Ostojic, Ivan Jurak

World of health · 2026 · 9 (1) · 16-21

DOI: 10.65241/wh.9.1.3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World of health, 2026. Verfasst von Sonja Ostojic und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The infrasternal angle (ISA) has recently gained attention as a potentially relevant clinical and kinematic parameter due to its associations with breathing patterns, abdominal muscle function and thoracic–pelvic interaction. However, the lack of a standardised measurement protocol and the variability of manual techniques limit its broader clinical and research application. Photogrammetry using Kinovea software may represent a practical and objective alternative, although its application to ISA measurement has not yet been systematically investigated. This study aimed to compare manual goniometry and Kinovea-based photogrammetry to assess their agreement for ISA measurement in healthy young adults, assuming a high level of inter-method agreement.

Methods

ISA was measured in 94 healthy young adults using manual goniometry and frontal photographs analysed in Kinovea. Continuous data were summarised using descriptive statistics; normality was assessed via the Shapiro–Wilk test. Systematic differences between methods were evaluated using a paired-samples t-test. Absolute agreement at the individual level was quantified using a two-way single measure intraclass correlation coefficient (ICC). Measurement error was characterised by the standard error of measurement (SEM) and minimal detectable change at the 95% confidence level (MDC95). Agreement was further examined using Bland–Altman analysis.

Results

The ICC (2,1) for absolute agreement was 0.955 (95% CI 0.941–0.970). SEM was 2.54°, and MDC95 was 7.04°. Bland–Altman analysis showed a mean bias of 1.63° with 95% limits of agreement from –4.84° to 8.09° with most values falling within these bounds.

Conclusions

Kinovea photogrammetry demonstrates excellent agreement with manual goniometry with small and consistent inter-method differences that fall below the MDC95 threshold. These findings indicate that Kinovea represents a reliable and methodologically consistent alternative to manual goniometry for ISA assessment, offering advantages such as objective documentation, reduced examiner dependency and suitability for research, education and large-scale data collection

Zitieren

APA

Ostojic, S., & Jurak, I. (2026). Comparison of manual goniometry and kinovea-based photogrammetry for infrasternal angle assessment. World of health, 9(1), 16-21. https://doi.org/10.65241/wh.9.1.3

Vancouver

Ostojic S, Jurak I. Comparison of manual goniometry and kinovea-based photogrammetry for infrasternal angle assessment. World of health. 2026;9(1):16-21. doi:10.65241/wh.9.1.3

BibTeX
@article{Ostojic2026,
  author = {Ostojic, Sonja and Jurak, Ivan},
  title = {Comparison of manual goniometry and kinovea-based photogrammetry for infrasternal angle assessment},
  journal = {World of health},
  year = {2026},
  volume = {9},
  number = {1},
  pages = {16--21},
  doi = {10.65241/wh.9.1.3}
}
Kostenlos starten →