A comparative study of pre-operative cone beam computed tomography findings versus intraoperative surgical findings of ossicular status in otosclerosis
Journal of MedVerse Research & Practice · 2025
DOI: 10.65188/nurexus.1018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of MedVerse Research & Practice, 2025. Verfasst von Sumathi Rao und 1 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Introduction
Otosclerosis is a primary bone disorder of the otic capsule characterized by abnormal bone remodeling, leading to progressive conductive hearing loss. Cone Beam Computed Tomography (CBCT) has emerged as a superior imaging modality for evaluating ossicular status due to its high spatial resolution and lower radiation exposure. This study aims to assess the correlation between preoperative CBCT findings and intraoperative surgical observations regarding the ossicular status in otosclerosis patients. Materials & Methods: A comparative observational study was conducted on 50 patients diagnosed with otosclerosis and scheduled for stapes surgery. Preoperative CBCT scans were performed to evaluate the ossicular chain, and intraoperative findings were documented to assess stapes fixation, ossicular mobility, and peri-cochlear hypodensity. The sensitivity, specificity, and accuracy of CBCT in predicting intraoperative findings were analyzed using statistical methods.
Results
Among the 50 patients, CBCT demonstrated an 85% sensitivity, 95% specificity, and 99% overall accuracy in detecting ossicular abnormalities. Stapes fixation was identified preoperatively in 26 cases, with a 75% intraoperative correlation. Ossicular chain mobility was detected in 31 cases, showing an 89% concordance. Peri-cochlear hypodensity had the highest intraoperative confirmation rate at 97%. The study found a slight male predominance (52%) and a right-sided predominance (70%) in otosclerosis cases.
Conclusion
CBCT is a reliable preoperative imaging tool for evaluating the ossicular status in otosclerosis, particularly in detecting peri-cochlear hypodensity and stapes fixation. However, its moderate positive predictive value (67%) indicates the need for intraoperative confirmation to avoid overestimation of abnormalities. Further research incorporating AI-assisted imaging analysis may enhance diagnostic accuracy and surgical planning. Keywords: Otosclerosis, Cone Beam Computed Tomography, Stapes Fixation, Ossicular Chain, Preoperative Imaging, Intraoperative Correlation
Zitieren
APA
Rao, S., & B, A. (2025). A comparative study of pre-operative cone beam computed tomography findings versus intraoperative surgical findings of ossicular status in otosclerosis. Journal of MedVerse Research & Practice. https://doi.org/10.65188/nurexus.1018
Vancouver
Rao S, B A. A comparative study of pre-operative cone beam computed tomography findings versus intraoperative surgical findings of ossicular status in otosclerosis. Journal of MedVerse Research & Practice. 2025. doi:10.65188/nurexus.1018
BibTeX
@article{Rao2025,
author = {Rao, Sumathi and B, Ahmed},
title = {A comparative study of pre-operative cone beam computed tomography findings versus intraoperative surgical findings of ossicular status in otosclerosis},
journal = {Journal of MedVerse Research & Practice},
year = {2025},
doi = {10.65188/nurexus.1018}
}
EUVIMED