EUVIMEDEUVIMED entdecken
Crossref

A hybrid comb teeth-friction damper for enhanced seismic resilience of RC hospital structures

R. Arvind, M. Helen Santhi, G. Malathi, Huseyin Bilgin

Ingegneria Sismica · 2025

DOI: 10.65102/is202532 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ingegneria Sismica, 2025. Verfasst von R. Arvind und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hospitals and other critical infrastructure must maintain operational functionality following seismic events, necessitating the development of advanced structural protection systems that can effectively mitigate earthquake-induced damage. This study presents a hybrid passive energy dissipation device, the Comb Teeth–Friction Damper (CTFD), developed by integrating the complementary mechanisms of a comb teeth damper (CTD) and a friction damper (FD) to enhance energy dissipation performance. The investigation was conducted in two phases. The component-level validation involved experimental monotonic testing of the CTFD, followed by numerical characterization under cyclic loading using ABAQUS. The results showed strong agreement between experimental and numerical responses, confirming the accuracy of the proposed model. Subsequently, a system-level performance assessment was carried out through nonlinear time history analyses (NTHA) on a detailed G+14 reinforced concrete hospital building equipped with various damper configurations, using ETABS software. A total of ninety-six analyses were performed across five structural models. A multi-criteria selection algorithm was used to identify the optimal damper configuration, based on minimizing roof displacement and inter-storey drift while maximizing energy dissipation. The optimal design, Model 5, with CTFDs placed in the central bay from the 6th to the 15th storey, demonstrated superior performance, dissipating nearly 80% of seismic energy, maintaining maximum inter-storey drift within 0.002, and achieving a 60% reduction in top-storey displacement. These findings validate the CTFD, when optimally positioned, as a highly efficient and practical solution for enhancing the seismic resilience of multi-storey RC hospital structures, outperforming its individual constituent dampers.

Zitieren

APA

Arvind, R., Santhi, M. H., Malathi, G., & Bilgin, H. (2025). A hybrid comb teeth-friction damper for enhanced seismic resilience of RC hospital structures. Ingegneria Sismica. https://doi.org/10.65102/is202532

Vancouver

Arvind R, Santhi MH, Malathi G, Bilgin H. A hybrid comb teeth-friction damper for enhanced seismic resilience of RC hospital structures. Ingegneria Sismica. 2025. doi:10.65102/is202532

BibTeX
@article{Arvind2025,
  author = {Arvind, R. and Santhi, M. Helen and Malathi, G. and Bilgin, Huseyin},
  title = {A hybrid comb teeth-friction damper for enhanced seismic resilience of RC hospital structures},
  journal = {Ingegneria Sismica},
  year = {2025},
  doi = {10.65102/is202532}
}
Kostenlos starten →