Tomographic medical imaging experiment through coincidence detection of non-collinear cascade gamma-ray emissions from an Indium-111 point-like source
Tanzania Journal of Science · 15.11.2026 · 52 (4)
DOI: 10.65085/2507-7961.2445 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tanzania Journal of Science, online erschienen am 15.11.2026. Verfasst von Leonid L Nkuba und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Following our previous GATE-based Monte Carlo simulation studies, a table-top experiment was performed to validate event-by-event image reconstruction for medical imaging. The prototype measured coincidences between 171.3 keV and 245.4 keV non- collinear gamma rays emitted by Indium-111 (111In) point-like source. This imaging modality combines the collimator-based imaging geometry of SPECT with the coincidence detection principle of PET. Based on the simulation results, a tungsten (W) and polylactic acid (PLA) collimator was fabricated using three-dimensional printing and was finally integrated with a small-animal PET system. Imaging was conducted using a 2.0 MBq point- like source (approximately 3.0 mm in diameter) positioned at the center of the field of view. This was followed by scanning multiple point-like sources of varying activities and configurations. Despite the limited spatial resolution of approximately 10.4 mm FWHM transaxially and 15.9 mm FWHM axially, resulting from septal penetration that ultimately broadens the point spread function, the system demonstrated a sensitivity of approximately 1.0 cps/MBq. While the system partially resolved two sources separated by 24.0 mm axially, it failed to resolve separations of 5.0 mm and 10.0 mm transaxially due to collimator material and fabrication limitations. These encouraging results support further optimization and extension of the approach to a full-body PET system.
Zitieren
APA
Nkuba, L. L., Olshanoski, K., Endo, S., Fukuchi, T., & Rangacharyulu, C. (2026). Tomographic medical imaging experiment through coincidence detection of non-collinear cascade gamma-ray emissions from an Indium-111 point-like source. Tanzania Journal of Science, 52(4). https://doi.org/10.65085/2507-7961.2445
Vancouver
Nkuba LL, Olshanoski K, Endo S, Fukuchi T, Rangacharyulu C. Tomographic medical imaging experiment through coincidence detection of non-collinear cascade gamma-ray emissions from an Indium-111 point-like source. Tanzania Journal of Science. 2026;52(4). doi:10.65085/2507-7961.2445
BibTeX
@article{Nkuba2026,
author = {Nkuba, Leonid L and Olshanoski, Kaylyn and Endo, Satoru and Fukuchi, Tomonori and Rangacharyulu, Chary},
title = {Tomographic medical imaging experiment through coincidence detection of non-collinear cascade gamma-ray emissions from an Indium-111 point-like source},
journal = {Tanzania Journal of Science},
year = {2026},
volume = {52},
number = {4},
doi = {10.65085/2507-7961.2445}
}
EUVIMED