External Multicenter Validation of an Artificial Intelligence System for Cone-Beam CT–Based Detection of Maxillofacial Fractures: Robustness Across a Tertiary Facial Trauma Clinic and an Independent Maxillofacial Practice

Ayhan Yildirim, René Hertach, Vedat Yildirim

Journal of Medicine and Dentistry · 15.04.2026 · 2 (1) · 70-81

DOI: 10.64951/jmdnt.2026.1.08 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medicine and Dentistry, online erschienen am 27.12.2025. Verfasst von Ayhan Yildirim und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Artificial intelligence (AI)–assisted interpretation of cone-beam computed tomography (CBCT), also referred to as digital volume tomography (DVT), has recently demonstrated high diagnostic accuracy for the detection of maxillofacial fractures in retrospective single-center studies [1,2]. Despite these promising results, concerns remain regarding the generalizability and robustness of AI models when applied to independent institutions, different clinical environments, and heterogeneous imaging protocols.

Objective

The aim of this study was to externally validate an AI-based system for automated detection of maxillofacial fractures on CBCT by assessing its diagnostic performance across two independent institutions with fundamentally different clinical settings: a tertiary referral facial trauma clinic in Zurich and an independent maxillofacial surgery practice in Munich.

Methods

In this retrospective multicenter validation study, CBCT scans from 282 adult patients with acute maxillofacial trauma were included (Center A: 150 patients; Center B: 132 patients). The AI system was developed and trained exclusively using data from Center A and subsequently applied to Center B without retraining or fine-tuning. Diagnostic performance metrics were calculated and compared with junior and senior clinician readers.

Results

Across both centers, the AI system achieved a sensitivity of 97.6%, a specificity of 96.4%, and an overall diagnostic accuracy of 97.1%. Performance remained consistent between the tertiary clinic and the independent practice. AI significantly outperformed junior clinicians and demonstrated diagnostic accuracy comparable to senior specialists, while substantially reducing time-to-diagnosis.

Conclusion

The AI system showed high robustness and external validity across different institutions and healthcare settings, supporting its suitability for broader clinical deployment in emergency maxillofacial trauma imaging.

Zitieren

APA

Yildirim, A., Hertach, R., & Yildirim, V. (2026). External Multicenter Validation of an Artificial Intelligence System for Cone-Beam CT–Based Detection of Maxillofacial Fractures: Robustness Across a Tertiary Facial Trauma Clinic and an Independent Maxillofacial Practice. Journal of Medicine and Dentistry, 2(1), 70-81. https://doi.org/10.64951/jmdnt.2026.1.08

Vancouver

Yildirim A, Hertach R, Yildirim V. External Multicenter Validation of an Artificial Intelligence System for Cone-Beam CT–Based Detection of Maxillofacial Fractures: Robustness Across a Tertiary Facial Trauma Clinic and an Independent Maxillofacial Practice. Journal of Medicine and Dentistry. 2026;2(1):70-81. doi:10.64951/jmdnt.2026.1.08

BibTeX
@article{Yildirim2026,
  author = {Yildirim, Ayhan and Hertach, René and Yildirim, Vedat},
  title = {External Multicenter Validation of an Artificial Intelligence System for Cone-Beam CT–Based Detection of Maxillofacial Fractures: Robustness Across a Tertiary Facial Trauma Clinic and an Independent Maxillofacial Practice},
  journal = {Journal of Medicine and Dentistry},
  year = {2026},
  volume = {2},
  number = {1},
  pages = {70--81},
  doi = {10.64951/jmdnt.2026.1.08}
}
Kostenlos starten →