Seismic Performance Evaluation of a Five Storey Cancer Hospital Building Using a Special Moment Resisting Frame System
Journal of Engineering Innovation and Management Science · 03.05.2026 · 2 (1) · 18-36
DOI: 10.64780/jeims.v2i1.14 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Engineering Innovation and Management Science, online erschienen am 03.05.2026. Verfasst von Randy Setiawan und 4 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
The development of specialized healthcare facilities is essential to improving access to cancer treatment, particularly in regions with limited oncology services. This study presents the structural design and seismic evaluation of a five-storey reinforced concrete cancer hospital building located in Pontianak City, West Kalimantan Province, Indonesia. The project aims to support the provision of safe and reliable healthcare infrastructure while ensuring compliance with national structural and seismic design standards.The structural planning was carried out using primary and secondary data obtained from the project site. The building is designed as a reinforced concrete system consisting of slabs, beams, and columns in accordance with the Indonesian concrete design code SNI 2847:2019. To address seismic demands, the structure adopts a Special Moment Resisting Frame (SMRF) system following the Indonesian seismic standard SNI 1726:2019. A three-dimensional structural model was developed using ETABS v18 software, and response spectrum analysis was applied to evaluate internal forces, inter-storey drift, and overall seismic behavior. The results indicate that the designed beam and column sections satisfy the cross-sectional and detailing requirements of the SMRF system. The strong-column weak-beam mechanism is consistently achieved, supporting ductile structural performance under seismic loading. Structural serviceability under design loads remains within permissible limits. In addition, the foundation system was designed based on cone penetration test data, demonstrating adequate bearing capacity and structural stability. This study provides a practical reference for the seismic-resistant design of hospital buildings in earthquake-prone regions and contributes to the development of resilient healthcare infrastructure in Indonesia.
Zitieren
APA
Setiawan, R., Dhaifullah, N., Qadrie, S. M. M. A., Setyanugraha, T., & Hillary, J. (2026). Seismic Performance Evaluation of a Five Storey Cancer Hospital Building Using a Special Moment Resisting Frame System. Journal of Engineering Innovation and Management Science, 2(1), 18-36. https://doi.org/10.64780/jeims.v2i1.14
Vancouver
Setiawan R, Dhaifullah N, Qadrie SMMA, Setyanugraha T, Hillary J. Seismic Performance Evaluation of a Five Storey Cancer Hospital Building Using a Special Moment Resisting Frame System. Journal of Engineering Innovation and Management Science. 2026;2(1):18-36. doi:10.64780/jeims.v2i1.14
BibTeX
@article{Setiawan2026,
author = {Setiawan, Randy and Dhaifullah, Nafis and Qadrie, SY. M. Miqdad Al and Setyanugraha, Tegar and Hillary, Janne},
title = {Seismic Performance Evaluation of a Five Storey Cancer Hospital Building Using a Special Moment Resisting Frame System},
journal = {Journal of Engineering Innovation and Management Science},
year = {2026},
volume = {2},
number = {1},
pages = {18--36},
doi = {10.64780/jeims.v2i1.14}
}
EUVIMED