EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Functional measurement of intermediate coronary stenosis using fractional flow reserve: Based Technique

Ahmed Moyed Hussein, Mahdi S. Yaser Alzaidi, Bashar Muhamad Abed

Ninevah University Journal of Medical Sciences · 2026

DOI: 10.64554/nujms.2026.2.1.5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ninevah University Journal of Medical Sciences, 2026. Verfasst von Ahmed Moyed Hussein und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Coronary angiography has limited ability to determine the functional significance of intermediate coronary lesions. Fractional flow reserve (FFR) provides a physiological assessment that can complement angiographic evaluation.

Objective

To evaluate the relationship between FFR and angiographic severity assessed by visual estimation and quantitative coronary angiography (QCA) in intermediate coronary lesions.

Methods

This cross-sectional observational study included 43 consecutive symptomatic patients with 53 intermediate coronary lesions evaluated at the catheterization laboratory of Ibn Al-Bitar Center for Cardiac Surgery and Cardiology between July and December 2013. Diameter stenosis was assessed visually by two interventional cardiologists and by QCA. Lesions were classified according to QCA into Group A (50–70% stenosis; 29 lesions) and Group B (30–49% stenosis; 24 lesions). FFR was measured during maximal hyperemia induced by intravenous or intracoronary adenosine using a pressure-wire system. A lesion was considered functionally significant when FFR was ≤0.80.

Results

Mean FFR was 0.87 ± 0.068 (range, 0.65–0.99). FFR was ≤0.80 in 5 of 29 lesions (17%; 95% confidence interval [CI], 6–36%) in Group A and in none of the 24 lesions in Group B (0%; 95% CI, 0–14%). The difference between groups was not statistically significant (Fisher’s exact test, P = 0.056), and agreement between angiographic group and FFR category was slight (κ = 0.16). QCA diameter stenosis showed a weak inverse correlation with FFR (r = −0.40, P = 0.003). Mean diameter stenosis was 50 ± 10.25% by QCA and 57 ± 11.14% by visual assessment. Adenosine-related adverse effects were predominantly minor; chest discomfort occurred in 15 patients (34.9%) and bradycardia below 50 beats/min in 8 (18.6%). No death or myocardial infarction occurred.

Conclusion

Angiographic severity showed only a weak relationship with the physiological significance of intermediate coronary lesions in this small single-center study. FFR may provide additional information when angiography alone is insufficient to determine lesion significance, although larger studies with clinical follow-up are required

Zitieren

APA

Hussein, A. M., Alzaidi, M. S. Y., & Abed, B. M. (2026). Functional measurement of intermediate coronary stenosis using fractional flow reserve: Based Technique. Ninevah University Journal of Medical Sciences. https://doi.org/10.64554/nujms.2026.2.1.5

Vancouver

Hussein AM, Alzaidi MSY, Abed BM. Functional measurement of intermediate coronary stenosis using fractional flow reserve: Based Technique. Ninevah University Journal of Medical Sciences. 2026. doi:10.64554/nujms.2026.2.1.5

BibTeX
@article{Hussein2026,
  author = {Hussein, Ahmed Moyed and Alzaidi, Mahdi S. Yaser and Abed, Bashar Muhamad},
  title = {Functional measurement of intermediate coronary stenosis using fractional flow reserve: Based Technique},
  journal = {Ninevah University Journal of Medical Sciences},
  year = {2026},
  doi = {10.64554/nujms.2026.2.1.5}
}
Kostenlos starten →