Failure Testing of the Proximal Femur in Multiple Load Configurations
Tobruk University Journal of Engineering Sciences · 30.12.2021 · 2 (2) · 28-44
DOI: 10.64516/tujes.v2i2.59 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tobruk University Journal of Engineering Sciences, online erschienen am 30.12.2021. Verfasst von Ali Gebriel und 1 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The main aim of this paper is to design and fabricate testing fixtures and attachments for loading ovine and human femur specimens to failure in stance and fall configurations. The fixtures will then be used to run the mechanical testing (failure testing), data acquisition, and data analysis for ovine and human femur specimens. All attachments are designed using Solidworks software, and are made of aluminum metal. The fixtures are designed to bolt onto our (MTS) in the lab. For human femur specimens ,the stance configuration maximum load force was (9801.18 N) comparing to (4466.92 N)for the fall configuration maximum load force. That means the stance maximum load force was (220%) higher than the fall maximum load force. The strength is less in the fall configuration because the human femur is adapted to the stance configuration. This paper has provided the testing capability that can be used to determine effects of diseases, provide inputs to computational models, and validate computational models in future studies of femur fracture strength.
Zitieren
APA
Gebriel, A., & Moftah, E. (2021). Failure Testing of the Proximal Femur in Multiple Load Configurations. Tobruk University Journal of Engineering Sciences, 2(2), 28-44. https://doi.org/10.64516/tujes.v2i2.59
Vancouver
Gebriel A, Moftah E. Failure Testing of the Proximal Femur in Multiple Load Configurations. Tobruk University Journal of Engineering Sciences. 2021;2(2):28-44. doi:10.64516/tujes.v2i2.59
BibTeX
@article{Gebriel2021,
author = {Gebriel, Ali and Moftah, Elmuataz},
title = {Failure Testing of the Proximal Femur in Multiple Load Configurations},
journal = {Tobruk University Journal of Engineering Sciences},
year = {2021},
volume = {2},
number = {2},
pages = {28--44},
doi = {10.64516/tujes.v2i2.59}
}
EUVIMED