EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Influence of Clay Percentage in Clay-Sand Mixture on Electroosmosis Permeability Value

Mohamed Ahmed, Aisha Naseab, Enteasar Khalifa, Wafa Mohammed, Hanin Alnaje

Tobruk University Journal of Engineering Sciences · 30.06.2020 · 1 (1) · 25-38

DOI: 10.64516/tujes.v1i1.63 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tobruk University Journal of Engineering Sciences, online erschienen am 30.06.2020. Verfasst von Mohamed Ahmed und 4 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The search for new and more effective methods of improving the stability of natural soils led to investigate the feasibility of soil stabilization by the application of electrical currents. Much research and many practical applications of electrical stabilization of soils have been reported. Electroosmosis is one of the processes that occur when an electric current is applied through saturated fine-grained soil. Applying an electrical potential to the saturated soil causes the hydrated positive ions to move toward the negative electrode, so pore water is transported by electroosmosis through the porous medium. In this paper, the theory of electroosmotic flow is summarized. The correlation between conventional soil characteristics and the most important electroosmotic parameters, soil resistivity and electroosmotic permeability coefficient, is indicated. The electroosmotic dewatering experiments were conducted with samples of soil with the dimensions of 10 cm long, 8 cm high, and 9 cm deep. Several laboratory tests have been performed on different mixtures of clay with natural sand to investigate soil behavior under electroosmosis. The results show that as the percentage of clay increases the coefficient of permeability value increases. Also, the study shows that the values of coefficient of permeability vary from 2.59 *10-10 m2/s.v to 2.9 10-9 m2/s.v.

Zitieren

APA

Ahmed, M., Naseab, A., Khalifa, E., Mohammed, W., & Alnaje, H. (2020). The Influence of Clay Percentage in Clay-Sand Mixture on Electroosmosis Permeability Value. Tobruk University Journal of Engineering Sciences, 1(1), 25-38. https://doi.org/10.64516/tujes.v1i1.63

Vancouver

Ahmed M, Naseab A, Khalifa E, Mohammed W, Alnaje H. The Influence of Clay Percentage in Clay-Sand Mixture on Electroosmosis Permeability Value. Tobruk University Journal of Engineering Sciences. 2020;1(1):25-38. doi:10.64516/tujes.v1i1.63

BibTeX
@article{Ahmed2020,
  author = {Ahmed, Mohamed and Naseab, Aisha and Khalifa, Enteasar and Mohammed, Wafa and Alnaje, Hanin},
  title = {The Influence of Clay Percentage in Clay-Sand Mixture on Electroosmosis Permeability Value},
  journal = {Tobruk University Journal of Engineering Sciences},
  year = {2020},
  volume = {1},
  number = {1},
  pages = {25--38},
  doi = {10.64516/tujes.v1i1.63}
}
Kostenlos starten →