EUVIMEDEUVIMED entdecken
Crossref

Impact of Dose Calculation Algorithms on IMRT Treatment Planning for Nasopharyngeal Carcinoma in India: Dosimetric Effects of Air Cavities and Bony Structures, Heterogeneity Correction, Target Coverage, and Organs-at-Risk Sparing

Ghritashee M. Swain, Zenab Ali Madi, Prabu J. Mathew, Mohan N. Kumar, Mohit Ram Das, Jamuna Shinde, Shankarappa Laskar, Kaustav Visumathi, Ramganesh Paul, Krishna B. Budrukkar

The International Journal of Applied Sciences · 2026

DOI: 10.64440/ijas/ijas101025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Applied Sciences, 2026. Verfasst von Ghritashee M. Swain und 9 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate dose calculation is fundamental to intensity-modulated radiation therapy (IMRT), particularly for nasopharyngeal carcinoma, where the target volume is surrounded by heterogeneous anatomical structures, including air cavities, skull-base bone, and radiosensitive organs. Differences between dose calculation algorithms may affect target coverage, dose distribution, and the reliability of treatment plan evaluation.

Objective

This study aimed to compare the Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) against an independent Monte Carlo (MC)-based dose calculation, focusing on the dosimetric effects of air cavities and bony structures within the primary planning target volume (PTV), target coverage, organ-at-risk (OAR) sparing, and the relationship between heterogeneous-structure volume and gamma passing rate. The findings are discussed in the context of radiotherapy practice in India.

Methods

The analyzed dataset comprised 20 nasopharyngeal carcinoma IMRT treatment plans. The original cohort included 11 male and 9 female patients aged 33–69 years, with a median age of 55 years. Plans were generated using Varian Eclipse treatment planning system (TPS) version 13.6, a Varian IX linear accelerator, 6-MV photons, a Millennium 120-leaf multileaf collimator, nine coplanar fields, and a 2.5-mm calculation grid. AAA- and AXB-calculated dose distributions were compared with independent Monte Carlo-based calculations using SciMoCa. The evaluation included target and OAR dosimetric parameters, three-dimensional gamma passing rates using 3%/2-mm criteria and a 10% dose threshold, and mean-dose deviations in air cavities and bony structures within the primary target. Paired comparisons and correlations between structure volume and gamma passing rate were reported.

Results

The overall gamma passing rates were 95.99 ± 1.06% for AAA and 96.26 ± 1.23% for AXB, with no statistically significant difference reported. For PGTVnx, the gamma passing rates were 93.77 ± 2.27% and 99.57 ± 0.23%, respectively. For PTV1, the corresponding values were 97.30 ± 1.26% and 99.71 ± 0.13%. Significant differences between the algorithms were also reported for the mandible and oral cavity. In air cavities, the mean-dose deviation was −2.26 ± 0.49% for AAA and −0.33 ± 0.63% for AXB. In bony structures, the respective deviations were 1.43 ± 0.68% and 0.17 ± 0.36%. The reported correlations between structure volume and AAA gamma passing rate were positive for air cavities (r = 0.65) and negative for bony structures (r = −0.74).

Conclusion

The findings indicate that algorithm-related discrepancies are concentrated in anatomically heterogeneous regions of nasopharyngeal carcinoma IMRT plans. AXB demonstrated closer agreement with the independent Monte Carlo reference in the evaluated air cavities and bony structures. Structure-specific dose evaluation, careful interpretation of target coverage, and independent verification may improve confidence in treatment planning.

Zitieren

APA

Swain, G. M., Madi, Z. A., Mathew, P. J., Kumar, M. N., Das, M. R., Shinde, J., Laskar, S., Visumathi, K., Paul, R., & Budrukkar, K. B. (2026). Impact of Dose Calculation Algorithms on IMRT Treatment Planning for Nasopharyngeal Carcinoma in India: Dosimetric Effects of Air Cavities and Bony Structures, Heterogeneity Correction, Target Coverage, and Organs-at-Risk Sparing. The International Journal of Applied Sciences. https://doi.org/10.64440/ijas/ijas101025

Vancouver

Swain GM, Madi ZA, Mathew PJ, Kumar MN, Das MR, Shinde J, et al. Impact of Dose Calculation Algorithms on IMRT Treatment Planning for Nasopharyngeal Carcinoma in India: Dosimetric Effects of Air Cavities and Bony Structures, Heterogeneity Correction, Target Coverage, and Organs-at-Risk Sparing. The International Journal of Applied Sciences. 2026. doi:10.64440/ijas/ijas101025

BibTeX
@article{Swain2026,
  author = {Swain, Ghritashee M. and Madi, Zenab Ali and Mathew, Prabu J. and Kumar, Mohan N. and Das, Mohit Ram and Shinde, Jamuna and Laskar, Shankarappa and Visumathi, Kaustav and Paul, Ramganesh and Budrukkar, Krishna B.},
  title = {Impact of Dose Calculation Algorithms on IMRT Treatment Planning for Nasopharyngeal Carcinoma in India: Dosimetric Effects of Air Cavities and Bony Structures, Heterogeneity Correction, Target Coverage, and Organs-at-Risk Sparing},
  journal = {The International Journal of Applied Sciences},
  year = {2026},
  doi = {10.64440/ijas/ijas101025}
}
Kostenlos starten →