EUVIMEDEUVIMED entdecken
Crossref

Dosimetric Comparison of Gamma Knife, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Recurrent High-Grade Glioma: Evaluation of Target Coverage, Dose Conformity, Organs-at-Risk Sparing, and Implications for Radiotherapy Practice in Indonesia

Vivin Ika Gavia, Zenab Ali Madi, Tarisha Bianca Hariono

The International Journal of Applied Sciences · 2026

DOI: 10.64440/ijas/ijas0025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Applied Sciences, 2026. Verfasst von Vivin Ika Gavia und 2 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recurrent high-grade glioma (HGG) presents a major therapeutic challenge because re-irradiation must balance adequate target coverage against the risk of radiation-induced injury to previously treated brain tissue. Gamma Knife (GK), fixed-field intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) offer different dose-distribution characteristics, but their relative dosimetric advantages may depend on target volume, shape, and treatment-planning strategy.

Objective

To compare GK, IMRT, VMAT, simultaneous integrated boost IMRT (SIB-IMRT), and simultaneous integrated boost VMAT (SIB-VMAT) plans for recurrent HGG, focusing on dose conformity, dose homogeneity, dose fall-off, maximum and mean target doses, and normal-brain exposure.

Methods

A comparative planning analysis was conducted using a dataset of 19 patients with recurrent HGG. Five radiotherapy planning approaches were evaluated: GK, fixed-field IMRT, VMAT, SIB-IMRT, and SIB-VMAT. Dosimetric endpoints included the conformity index (CI), homogeneity index (HI), gradient index (GI), maximum dose (Dmax), mean dose (Dmean), and normal-brain V5 and V12. The supplied dataset was analyzed using reported means, standard deviations, and paired comparisons. The geographic origin of the patient cohort and the institutional details of the original ethics approval must be verified and accurately reported before publication; the present analysis does not establish that the patients were treated in Indonesia.

Results

GK produced the lowest reported GI (2.87 ± 0.36), compared with 4.13 ± 0.84 for IMRT, 4.08 ± 0.86 for VMAT, 4.23 ± 0.96 for SIB-IMRT, and 3.95 ± 0.68 for SIB-VMAT. The reported CI was lower for GK (0.77 ± 0.09) than for the four linear-accelerator approaches (0.92–0.93). Conventional IMRT and VMAT had lower HI values (1.03 ± 0.02 and 1.06 ± 0.02, respectively) than GK and the SIB approaches (1.85–1.96). Normal-brain V12 was lowest with GK (31.93 ± 11.97), compared with 41.22–43.61 across the linear-accelerator plans. Differences between GK and each linear-accelerator approach in V12 were reported as statistically significant (all P < 0.001). The reported V5 differences between GK and conventional IMRT or VMAT were not statistically significant. SIB plans showed higher reported Dmax and Dmean values than conventional IMRT and VMAT, consistent with their intended intratarget dose escalation.

Conclusion

In this planning dataset, GK showed the steepest reported dose gradient and the lowest normal-brain V12, whereas IMRT and VMAT demonstrated better reported conformity and homogeneity. SIB approaches generated higher target dose values than conventional plans. These findings support individualized plan selection according to lesion size, geometry, prior irradiation, and normal-tissue constraints. Clinical conclusions, claims of treatment efficiency, and application to Indonesian patients require confirmation through verified source documentation, additional treatment-delivery data, and clinical outcome evaluation.

Zitieren

APA

Gavia, V. I., Madi, Z. A., & Hariono, T. B. (2026). Dosimetric Comparison of Gamma Knife, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Recurrent High-Grade Glioma: Evaluation of Target Coverage, Dose Conformity, Organs-at-Risk Sparing, and Implications for Radiotherapy Practice in Indonesia. The International Journal of Applied Sciences. https://doi.org/10.64440/ijas/ijas0025

Vancouver

Gavia VI, Madi ZA, Hariono TB. Dosimetric Comparison of Gamma Knife, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Recurrent High-Grade Glioma: Evaluation of Target Coverage, Dose Conformity, Organs-at-Risk Sparing, and Implications for Radiotherapy Practice in Indonesia. The International Journal of Applied Sciences. 2026. doi:10.64440/ijas/ijas0025

BibTeX
@article{Gavia2026,
  author = {Gavia, Vivin Ika and Madi, Zenab Ali and Hariono, Tarisha Bianca},
  title = {Dosimetric Comparison of Gamma Knife, Intensity-Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Recurrent High-Grade Glioma: Evaluation of Target Coverage, Dose Conformity, Organs-at-Risk Sparing, and Implications for Radiotherapy Practice in Indonesia},
  journal = {The International Journal of Applied Sciences},
  year = {2026},
  doi = {10.64440/ijas/ijas0025}
}
Kostenlos starten →