EUVIMEDEUVIMED entdecken
Crossref

Determination of Entrance Skin Dose from Diagnostic Chest X-Ray at Federal University of Health Sciences Teaching Hospital, Azare, Nigeria

Ahmad halifa Yusuf, Dauda Abubakar, Auwalu Baballe, Magili ibrahim, S. A. Dalhatu

BIMA JOURNAL OF SCIENCE AND TECHNOLOGY GOMBE · 2026

DOI: 10.64290/bima.v10i1a.1533 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BIMA JOURNAL OF SCIENCE AND TECHNOLOGY GOMBE, 2026. Verfasst von Ahmad halifa Yusuf und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to investigate entrance skin dose (ESDs) and the consequent health risk for the 20 patients undergoing diagnostic posterior anterior (PA) Chest X-ray examinations at federal university of health sciences teaching hospital, azare. The ESDs were calculated for each patient based on their specific exposure parameters: tube voltage (kVp), tube current (mAs) and focus to skin Distance (FSD). The results indicated a range of values between 0.18 mGy and 0.39 mGy, with a mean value of 0.26 mGy. The average ESD obtained was within the WHO’s recommended limit of 0.3 mGy when compared to the standard dose typically received by patients during chest X-ray examinations. Nonetheless, results showed that four samples, specifically S4, S10, S18, and S19, had ESD values exceeded the permissible limit, with corresponding values of 0.37, 0.39, 0.36, and 0.35 mGy., respectively. The findings also demonstrate that variations in kVp and mAs settings influence the resulting ESD, highlighting their importance in optimizing imaging techniques and reducing radiation dose. There is a need for continuous monitoring and optimizing radiation doses to guarantee that patients receive only the minimum dose required for accurate diagnosis while reducing potential radiation risks.

Zitieren

APA

Yusuf, A. H., Abubakar, D., Baballe, A., ibrahim, M., & Dalhatu, S. A. (2026). Determination of Entrance Skin Dose from Diagnostic Chest X-Ray at Federal University of Health Sciences Teaching Hospital, Azare, Nigeria. BIMA JOURNAL OF SCIENCE AND TECHNOLOGY GOMBE. https://doi.org/10.64290/bima.v10i1a.1533

Vancouver

Yusuf AH, Abubakar D, Baballe A, ibrahim M, Dalhatu SA. Determination of Entrance Skin Dose from Diagnostic Chest X-Ray at Federal University of Health Sciences Teaching Hospital, Azare, Nigeria. BIMA JOURNAL OF SCIENCE AND TECHNOLOGY GOMBE. 2026. doi:10.64290/bima.v10i1a.1533

BibTeX
@article{Yusuf2026,
  author = {Yusuf, Ahmad halifa and Abubakar, Dauda and Baballe, Auwalu and ibrahim, Magili and Dalhatu, S. A.},
  title = {Determination of Entrance Skin Dose from Diagnostic Chest X-Ray at Federal University of Health Sciences Teaching Hospital, Azare, Nigeria},
  journal = {BIMA JOURNAL OF SCIENCE AND TECHNOLOGY GOMBE},
  year = {2026},
  doi = {10.64290/bima.v10i1a.1533}
}
Kostenlos starten →