Hotspot-Induced Performance Degradation and Safety Risks in Aged Polycrystalline Photovoltaic Modules Evaluated Using IEC 61215 Standard
Renewable Energy and Power Quality Journal · 27.04.2026 · 24 (2) · 20-29
DOI: 10.64229/h91gqg94 ↗Kurz gefasst
Fachartikel in der Zeitschrift Renewable Energy and Power Quality Journal, online erschienen am 27.04.2026. Verfasst von Akila Djoudi Gherbi und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study presents a quantitative assessment of early stabilization losses and hotspot-induced degradation in polycrystalline photovoltaic (PV) modules following IEC 61215 procedures. Six new 100 W modules were subjected to controlled outdoor stabilization under cumulative irradiance exposures of 5 and 10 kWh/m2, while ten aged 260 W modules exposed for two years under open-circuit (Voc) conditions were evaluated under induced partial-shading hotspot stress. Electrical performance was characterized under standard test conditions (STC) using I-V measurements, complemented by infrared thermography and visual inspection. Stabilization testing revealed maximum power (Pmax) reductions of 3-5% after 5 kWh/m2 and up to 10% after 10 kWh/m2 exposure, with fill factor decreases of approximately 1-2%. In aged modules, hotspot activation produced localized temperatures exceeding 90 °C, surpassing the IEC acceptance threshold of 85 °C. Post-stress measurements showed irreversible Pmax losses ranging from 8% to 17%, accompanied by short-circuit current reductions of up to 4% and visible encapsulant browning and interconnect degradation. The combined effects indicate potential cumulative output losses exceeding 20% relative to nameplate ratings. These results emphasize the importance of rigorous stabilization and hotspot qualification testing to ensure long-term reliability, safety, and energy yield of PV modules operating under real-world conditions.
Zitieren
APA
Gherbi, A. D., Hafdaoui, H., & Belhaouas, N. (2026). Hotspot-Induced Performance Degradation and Safety Risks in Aged Polycrystalline Photovoltaic Modules Evaluated Using IEC 61215 Standard. Renewable Energy and Power Quality Journal, 24(2), 20-29. https://doi.org/10.64229/h91gqg94
Vancouver
Gherbi AD, Hafdaoui H, Belhaouas N. Hotspot-Induced Performance Degradation and Safety Risks in Aged Polycrystalline Photovoltaic Modules Evaluated Using IEC 61215 Standard. Renewable Energy and Power Quality Journal. 2026;24(2):20-29. doi:10.64229/h91gqg94
BibTeX
@article{Gherbi2026,
author = {Gherbi, Akila Djoudi and Hafdaoui, Hichem and Belhaouas, Nasreddine},
title = {Hotspot-Induced Performance Degradation and Safety Risks in Aged Polycrystalline Photovoltaic Modules Evaluated Using IEC 61215 Standard},
journal = {Renewable Energy and Power Quality Journal},
year = {2026},
volume = {24},
number = {2},
pages = {20--29},
doi = {10.64229/h91gqg94}
}