Abstract (Originalsprache)

Modern materials research depends on automated measurement systems that can eliminate errors from sample preparation and mounting hardware. This study develops a Python-scripted signal processing workflow that achieves consistent, hardware- independent measurements in Powder X-ray diffraction, an important characterization technique for battery materials, semiconductors and electronic devices. Using a custom GSAS-II automation script, we systematically tested four distinct sample- mounting designs (3D-printed polymer, steel, hybrid polymer-capped steel and commercial zero-background holder) that differ in material composition and geometry, properties known to cause measurement bias in XRD. Eight measurements were collected per mounting design (32 total datasets for TiO2 reference material; 16 datasets for battery cathode materials NCM 811 and NCM 622). The automated workflow applied the same instrument settings and analysis steps to every dataset, extracting structural parameters, peak positions and signal characteristics without any manual adjustments. Despite the hardware differences between mounts, statistical analysis showed that refined lattice parameters were identical across all mounting types (one-way ANOVA: p ≥ 0.05 for both a and c), achieving measurement precision of ±0.001 Å approaching research-grade accuracy on a benchtop system. Raw peak position differences between mounts were minimal (< 0.05◦ in 2θ) and all automated analyses converged with strong signal-to- model agreement (Rwp ≤ 15%). Testing on NCM battery cathode materials confirmed the same hardware-independent results with small systematic errors. This study establishes an automated, open-source framework that can accelerate XRD-based materials screening for batteries, electronics and sensors. The python-based approach demonstrates how software can correct for hardware differences in measurement systems, advancing the goal of achieving more dependable automated characterization.

Zitieren

APA

Sarode, S. A. (2025). Python-Scripted Signal Processing Workflow Eliminates Sample-Mount Bias in PXRD of Battery Electrode Materials. Journal of Engineering and Artificial Intelligence. https://doi.org/10.64142/jeai.1.3.35

Vancouver

Sarode SA. Python-Scripted Signal Processing Workflow Eliminates Sample-Mount Bias in PXRD of Battery Electrode Materials. Journal of Engineering and Artificial Intelligence. 2025. doi:10.64142/jeai.1.3.35

BibTeX
@article{Sarode2025,
  author = {Sarode, Shone A},
  title = {Python-Scripted Signal Processing Workflow Eliminates Sample-Mount Bias in PXRD of Battery Electrode Materials},
  journal = {Journal of Engineering and Artificial Intelligence},
  year = {2025},
  doi = {10.64142/jeai.1.3.35}
}
Kostenlos starten →