EUVIMEDEUVIMED entdecken
Querschnittstudie

Exhaled Breath Condensate as a Non-Invasive Biomarker of Oxidative Stress in Smokers: A Cross-Sectional Case–Control Study

Hassan H. Al-Salamy

Journal of Progressive Medical Sciences · 30.11.2025 · 1 (3)

DOI: 10.63939/vfzgj933 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Journal of Progressive Medical Sciences, online erschienen am 30.11.2025. Verfasst von Hassan H. Al-Salamy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction: smoking remains a major global health burden, driving disease through persistent oxidative stress and impaired antioxidant defenses. Traditional serum assays provide valuable information but are invasive and impractical for large-scale screening. Exhaled breath condensate (EBC) offers a simple, non-invasive alternative for assessing oxidative biomarkers in the airways.

Objectives

This study aimed to evaluate whether oxidative stress biomarkers measured in EBC reflect systemic oxidative changes in apparently healthy smokers and to determine their diagnostic performance.

Methods

A cross-sectional, case–control study was conducted among 60 adults (30 smokers, 30 non-smokers) aged 18–45 years. EBC was collected using a standardized condenser system, and both EBC and serum samples were analyzed for hydrogen peroxide (H₂O₂), 8-isoprostane, malondialdehyde (MDA), and total antioxidant capacity (TAC). Data were analyzed using t-tests, correlation analyses, and receiver-operating-characteristic (ROC) curves.

Results

Smokers showed markedly higher oxidative-stress biomarkers in both EBC and serum compared with non-smokers. Mean EBC H₂O₂ was 1.84 ± 0.42 µM in smokers versus 0.96 ± 0.28 µM in controls (p < 0.001), and EBC 8-isoprostane levels were 57.4 ± 14.3 pg/mL versus 33.1 ± 10.8 pg/mL (p < 0.001). TAC values were significantly lower in smokers across both matrices. EBC H₂O₂ correlated strongly with serum MDA (r = 0.61, p < 0.01), indicating concordant airway and systemic oxidative stress. ROC analysis showed high diagnostic accuracy for EBC H₂O₂ (AUC = 0.87, 95% CI 0.77–0.95).

Conclusions

EBC biomarkers, particularly H₂O₂ and 8-isoprostane, reliably mirror systemic oxidative stress in cigarette smokers. The strong correlation between EBC and serum markers supports EBC as a non-invasive, reproducible, and clinically relevant tool for early detection of smoking-related oxidative injury. Its simplicity and low cost make it especially promising for preventive health programs and research in low- and middle-income settings

Zitieren

APA

Al-Salamy, H. H. (2025). Exhaled Breath Condensate as a Non-Invasive Biomarker of Oxidative Stress in Smokers: A Cross-Sectional Case–Control Study. Journal of Progressive Medical Sciences, 1(3). https://doi.org/10.63939/vfzgj933

Vancouver

Al-Salamy HH. Exhaled Breath Condensate as a Non-Invasive Biomarker of Oxidative Stress in Smokers: A Cross-Sectional Case–Control Study. Journal of Progressive Medical Sciences. 2025;1(3). doi:10.63939/vfzgj933

BibTeX
@article{AlSalamy2025,
  author = {Al-Salamy, Hassan H.},
  title = {Exhaled Breath Condensate as a Non-Invasive Biomarker of Oxidative Stress in Smokers: A Cross-Sectional Case–Control Study},
  journal = {Journal of Progressive Medical Sciences},
  year = {2025},
  volume = {1},
  number = {3},
  doi = {10.63939/vfzgj933}
}
Kostenlos starten →