EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Comparison of combined torsional and conventional ultrasound mode versus torsional ultrasound mode phacoemulsification in different machines

Jiyoung Emily Lee, Eun Chul Kim

Insights in Cataract and Refractive Surgery · 30.06.2026 · 11 (2) · 40-46

DOI: 10.63375/icrs.25.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Insights in Cataract and Refractive Surgery, erschienen am 30.06.2026. Verfasst von Jiyoung Emily Lee und 1 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to compare the clinical outcomes of phacoemulsification performed using a combined torsional and conventional ultrasound mode versus torsional ultrasound mode alone in cataract surgery.

Methods

Sixty-five patients who underwent phacoemulsification using combined torsional and conventional ultrasound mode with the Cube alpha system (Nidek Co.) were compared with 300 patients who underwent phacoemulsification using torsional ultrasound mode alone with the Centurion system (Alcon Research Ltd.). The two groups were classified as N3, N4, N5, or N6 according to the Lens Opacities Classification System III. In each subgroup, phacoemulsification time (seconds), cumulative dissipated energy (CDE), balanced salt solution (BSS) use, and postoperative best-corrected visual acuity were analyzed and compared between the combined-mode group and the torsional-only group.

Results

In the N4–N6 subgroups, the torsional-only group had significantly longer phacoemulsification times and higher CDE values than the combined-mode group (P

Zitieren

APA

Lee, J. E., & Kim, E. C. (2026). Comparison of combined torsional and conventional ultrasound mode versus torsional ultrasound mode phacoemulsification in different machines. Insights in Cataract and Refractive Surgery, 11(2), 40-46. https://doi.org/10.63375/icrs.25.018

Vancouver

Lee JE, Kim EC. Comparison of combined torsional and conventional ultrasound mode versus torsional ultrasound mode phacoemulsification in different machines. Insights in Cataract and Refractive Surgery. 2026;11(2):40-46. doi:10.63375/icrs.25.018

BibTeX
@article{Lee2026,
  author = {Lee, Jiyoung Emily and Kim, Eun Chul},
  title = {Comparison of combined torsional and conventional ultrasound mode versus torsional ultrasound mode phacoemulsification in different machines},
  journal = {Insights in Cataract and Refractive Surgery},
  year = {2026},
  volume = {11},
  number = {2},
  pages = {40--46},
  doi = {10.63375/icrs.25.018}
}